[Source:]Current[:Level][:Immediate][:Amplitude] <Nrf; [Source:]Current[:Level][:Immediate][:Amplitude] - ITech IT8500+ Series Programming Manual

Dc programmable electronic load
Hide thumbs Also See for IT8500+ Series:
Table of Contents

Advertisement

*RST Value
CURRent
Examples
MODE RES

[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]

<NRf+>
This command is used to set the current setting in CC mode.
Command Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
A
*RST Value
MINimum
Examples
CURR 5
Query Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
Returned Parameters
<NR2>
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
This command is used to query the current setting in CC mode.
Command Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
CURRent: Constant Current Mode
VOLTage: Constant Voltage Mode
POWer: Constant Power Mode
RESistance: Constant Resistance Mode
DYNamic: Dynamic Operation Mode
LED: LED Mode
IMPedance: Constant Impedance Mode
Copyright © ITECH Electronic Co., Ltd.
Input Settings
33

Hide quick links:

Advertisement

Table of Contents
loading