E058
E065
current modulation alarm
E086
obstruction fumes alarm
Warning lights
BOILER STATUS
Power-on
Vent cycle
flashing 0.5 sec. on/1 sec. off
OFF status
No heat request (stby)
Transitional ignition/
overtemperature
Presence of flame
Chimney sweep
Screed heater
flashing 1 sec. on/1 sec. off
4.21
INFO menu
Pressing key 3 on the display screen displays a list of information regarding the operation of
the boiler listed by parameter name and value. Passing from the display of one parameter
to the next takes place by pressing respectively the keys
allows the selected parameter to be displayed; pressing the key
main screen:

PARAMETER NAME

SCREED HEATING HOURS
CH PROBE
RETURN PROBE
DHW PROBE
HW TANK LOW
COLLECTOR TEMP
EXHAUST PROBE
OUTDOOR TEMP PROBE
FILTERED OUTDOOR TEMP
FAN SPEED
MAIN ZONE OUTLET
EXHAUST PROBE HOURS
MAIN ZONE SET
WATER PRESSURE
ELECTRONIC BOARD ID
ELECTRONIC BOARD FMW
INTERFACE FMW
4.22

Temporary switch-off

In the event of temporary absences (weekends, short breaks, etc.) set the status of the
boiler to OFF
.
While the electrical supply and the fuel supply remain active, the boiler is protected by the
systems:
- heating anti-freeze: this function is activated if the temperature measured by the flow sensor
drops below 5°C. A heat request is generated in this phase with the ignition of the burner at
minimum output, which is maintained until the outlet water temperature reaches 35° C;
- domestic hot water anti-freeze (only with water tank with probe): this function is
activated if the temperature measured by the water tank probe drops below 5°C. A heat
request is generated in this phase with the ignition of the burner at minimum output,
which is maintained until the outlet water temperature reaches 55° C.
b
The operation of the ANTI-FREEZE function is indicated by a scrolling message
on the interface display: <<DHW ANTIFREEZE FUNCTION IN PROGRESS>> or
<<CH ANTIFREEZE FUNCTION IN PROGRESS>>, as the case may be.
- circulator anti-locking: the circulator activates every 24 hours of stoppage for 30
seconds.
mains voltage fault
RED LED
GREEN LED
flashing 0.5 sec. on/1 sec. off
flashing 0.3 sec. on/0.5 sec. off
flashing 0.3 sec. on/0.5 sec. off
flashing 0.3 sec. on/0.5 sec. off
flashing 1 sec. on/1 sec. off
and
. Pressing the key
returns you to the
DESCRIPTION
Number of hours passed with screed heating function
Boiler flow sensor value
Boiler return sensor value
Domestic hot water probe value when boiler in instantaneous mode
Water tank probe value high when boiler in heating only mode
Value of low water tank probe (if solar water tank connected)
Value of solar collector probe (if solar water tank connected)
Flue gas probe value
Outdoor temperature sensor instantaneous value
Outdoor temperature filtered value used in the thermoregulation algorithm for calculating the heating setpoint
Number of turns of the fan (rpm)
Main zone flow sensor value (when MAIN ZONE ACTUATION TYPE = 1)
Number of hours the heat exchanger has been operating in "condensing mode"
Main zone delivery setpoint
System pressure
Electronic board card identification
Electronic board card fmw revision
Interface fmw
ON
ON
Temporary fault reported during the post ventilation. It is maintained a post ventilation of 5
ON
RED and GREEN
flashing 0.5 sec. on/0.5 sec. off
ON
ON
4.23
Switching off for lengthy periods
The long term non use of the boiler causes the following operations to be carried out:
- set the status of the boiler to
- set the system's main switch to "off"
- close the fuel and water taps of the heating and domestic hot water system.
In this case, the anti-freeze and anti-blocking systems are deactivated. Drain the heating
and domestic water system if there is any risk of freezing
These are temporary faults that restrict the ignition cycle.
min at maximum fan speed.
NOTES
The red and green LEDs come on at the same time
The red and green LEDs come sequentially one at a time
Only if the flame is present
The red and green LEDs come on alternately
Closing
position
ENGLISH
23