Adjusting The Heating Water Temperature Without An Outdoor Temperature Sensor Connected; Reset Function; Adjusting The Heating Water Temperature With An Outdoor Temperature Sensor Connected - Beretta MYNUTE X R Installer And User Manual

Hide thumbs Also See for MYNUTE X R:
Table of Contents

Advertisement

Available languages

Available languages

4.8
Adjusting the heating water temperature without an outdoor
temperature sensor connected
If there is no outdoor temperature sensor the boiler operates at a fixed point, the HEATING
setpoint in this case can be set on the main page of the screen. Pressing the key C or D
displays the current heating setpoint; the value blinks with a frequency of 0.5 sec ON, 0.5
sec OFF and the icons
and
+
The successive pressing of the key C or D allows you to set the value of the heating setpoint
within the preset range:
[40°C - 80.5°C] for high temperature systems
[20°C - 45 °C] for low temperature systems
with steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with respect to the
operating range:
- four bars on = max setpoint.
- one bar on = min setpoint
Keeping one of the two keys C or D pressed for longer, the meter increases the speed of
advancement modifying the set value. If no key is pressed for 5sec, the value set is taken
as the new heating setpoint and the display returns to the main page.
4.9
Adjusting the heating water temperature with an outdoor
temperature sensor connected
If an outdoor temperature sensor is installed and thermoregulation is enabled (parameter
OTR=1), the delivery temperature is automatically selected by the system, which quickly
adjusts the ambient temperature according to the variations in the outdoor temperature. If
you want to change the temperature, raising it or lowering it with respect to the temperature
automatically calculated by the electronic board, it is possible to change the HEATING setpoint
as follows: press the keys C or D and select the desired level of comfort within the range (-5 -
+5) (see paragraph "4.5 Setting the thermoregulation" ).
Note: if an outdoor temperature sensor is connected it is in any event possible to have the
boiler operate at a fixed point by setting the parameter OTR = 0 (menu CH).
4.10
Adjusting the domestic hot water temperature
A CASE: Only heating with no water tank - regulation not applicable.
B CASE: Only heating + external water tank managed by a thermostat - regulation not
applicable.
C CASE: Only heating + external water tank managed by a probe - to adjust the temperature
of the domestic hot water stored in the water tank, proceed as follows:
On the main screen, pressing the key A rather than B displays the current domestic hot
water setpoint, the value blinks with a frequency of 0.5 sec ON, 0.5 sec OFF and the icons
and
come on.
come on.
C
+
D
RESET
MENU
A
+
B
The successive pressing of the keys A or B allows you to set the value of the domestic hot
water setpoint raising or lowering the value within the preset range in steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with respect to the
operating range:
- four bars on = max setpoint
- one bar on = min setpoint
4.11
Safety stop
If there are ignition faults or boiler operation malfunctions, carry out a "SAFETY STOP". On
the display, in addition to the fault code, the icon
frequency of 0.5sec ON and 0.5sec OFF.
The backlight blinks for 1min after which it switches off, while the icon
On the 4 digits a message scrolls containing the error code and its description.
4.12

Reset function

The RESET icon comes on when there is an alarm that requires a manual reset by the user
(for example flame lockout). To reset press key 2 RESET.
If the release attempts do not restart the boiler, contact your local Technical Assistance
Centre.
4.13
Screed heating function
For a low temperature system the boiler has a "screed heating" function that can be
activated in the following way:
ƒ set the boiler to OFF by pressing button 1
ƒ access the technical parameters menu, as indicated in the paragraph "3.19 Access to
the parameters"
ƒ select the CH menu and then SCREED HEATING with the keys
the selection with
.
(Note: SCREED HEATING is not available if the boiler is a status other than OFF).
ƒ To activate the function set the parameter to 1, to deactivate it set the parameter to 0.
The "screed heater" function lasts 168 hours (7 days) during which, in the zones configured
as low temperature, a heating request is simulated with an initial zone outlet of 20°C, then
increased in line with the table on the side.
+
RESET
MENU
is also displayed, which blinks with a
continues blinking.
DAY
DAY
RESET
,
ENGLISH
, confirming
19