For fault E041
If the pressure drops below the safety threshold of 0.3 bar the boiler displays the fault code
<<E041 water transducer load the system>> for a transitional time of 30sec.
When the transitional time has finished, if the fault persists the fault code E040 is displayed.
When the boiler has fault E040 manual loading should be carried out using the filling tap (external
to the boiler) until the pressure is between 1 and 1.5 bar. Then press RESET.
Close the filling tap (external to the boiler), making sure to hear the mechanical snap. At the end
of the procedure, proceed with the automatic vent cycle as described in the section "3.15 Filling
the heating system and eliminating air".
b
If the drop in pressure is very frequent, contact the Technical Assistance Centre.
Boiler faults list
ERROR
ERROR MESSAGE
CODE
E010
flame lockout/ACF electronic fault
E011
extraneous flame
E020
limit thermostat
E030
fan fault
E040
water transducer – load the system
E041
water transducer - load the system
E042
water pressure transducer fault
E060
storage tank probe fault
fault flow sensor/overtemperature flow sensor/
E070
flow/return sensor differential alarm
E077
main zone water thermostat
fault return line probe/return line probe overtemperature/
E080
outlet/return line probe differential alarm
fault flue gases probe/
E090
flue gases overtemperature probe
E091
clean primary heat exchanger
E099
reset attempts exhausted, boiler blocked
--
water pressure low - check the system
--
water pressure high - check the system
--
boiler board communication lost
--
BUS 485 communication lost
List of combustion faults
ERROR CODE
E021
E022
E023
E024
E067
E088
E097
E085
incomplete combustion
E094
incomplete combustion
E095
incomplete combustion
22
DAY
flashing 0.2 sec. on/0.2 off
flashing 0.5 sec. on/0.5 off
ERROR MESSAGE
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
iono alarm
For fault E060
The appearance of the E060 fault, on models with water tank with probe connected,
prevents sanitary operation.
For fault E091
The boiler has an auto-diagnostic system which, based on the total number of hours in
certain operating conditions, can signal the need to clean the primary exchanger (alarm
code E091). Once the cleaning operation (made with special kit supplied as an accessory)
it is necessary to reset to zero the total hour meter following procedure indicated below:
ƒ access the technical parameters as explained in the section "3.19 Access to the
parameters"
ƒ select the CONF menu and then EXHAUST PROBE RESET with the keys
ƒ set the parameter to 1 confirming the selection with
NOTE: The meter resetting procedure should be carried out after each in-depth cleaning
of the primary exchanger or if this latter is replaced.
The total hours can be verified in the following way:
ƒ access the INFO menus as indicated in the paragraph "4.21 INFO menu" at EXHAUST
PROBE RESET to display the value of the flue gases probe meter.
RED LED
GREEN LED
ON
ON
flashing 0.5 sec. on/0.5 off
ON
ON
ON
It is referred to the last fault occurred
flashing 0.5 sec. on/0.5 off
flashing 0.5 sec. on/0.5 off
ON
ON
LED
LED
RED
GREEN
ON
ON
These are temporary alarms that if they occur 6 times in an hour they become definitive;
ON
the alarm E097 is displayed and is followed by post-purging for 45 seconds at the fan's
ON
maximum speed. It is not possible to release the alarm before the end of the post-purging
ON
unless the boiler's power supply is switched off.
ON
ON
ON
These are temporary alarms that if they occur several times in an hour they become de-
finitive; the last error to occur is displayed and is followed by a post-purging of 5 minutes
ON
at the fan's maximum speed. It is not possible to release the alarm before the end of the
ON
Enter
RED and GREEN
ON
ON
flashing 0.5 sec. on/0.5 off
flashing 0.5 sec. on/0.5 off
flashing 0.5 sec. on/0.5 off
DESCRIPTION OF TYPE OF ALARM
post-purging unless the boiler's power supply is switched off.
and
.
DESCRIPTION OF TYPE
OF ALARM
definitive
transitional
definitive
definitive
definitive
transitional
definitive
transitional
transitional/definitive/
definitive
transitional
transitional/definitive/
definitive
transitional
definitive
transitional
definitive, not resettable
transitional
transitional
transitional
transitional

Advertisement

Table of Contents
loading

Table of Contents