EXTERNAL UNIT ERROR LIST
TDM
DESCRIPTION
ERROR
906
HP FAN Mismatch Error
907
HP V4W Mismatch Error
908
HP EXV Mismatch Error
909
HP Zero Fan Speed
910
HP Comunication error
911
HP TE Error
912
HP V4W Error Service
913
HP LWT Error
914
HP TR Error
916
HP TEO Error
917
HP Freeze Service
918
HP Pump Down Error
919
HP HIGH SDT Error
922
HP Freeze Error
931
HP INVERTER Error
937
No circulation error
946
HP compressor error
947
HP V4W Error
948
HP TD Error
949
HP TS Error
950
HP HIGH TD Service
951
HP HIGH TD Error
952
HP TO Error
HP Compressor Heater
953
Mismatch
HP Base Panel Heater
954
Mismatch
HP Compressor model
956
mismatch
957
HP Fan model mismatch
960
HP EWT Error
86 / GB
RESET
HP POWER
SERVICE
OFF
RESET
x
x
x
x
x
--
--
x
--
--
--
--
--
--
--
x
--
--
x
x
--
--
x
x
x
--
--
--
--
--
x
x
--
--
--
--
--
--
--
--
--
--
--
--
INVERT-
ER
DESCRIPTION
ERROR
1
Heat Sink-Overheat
2
Compressor Ipm Over-Current
3
Compressor Fail To Drive
4
Compressor Over-Current
5
Input Voltage Lack Of Phase
6
Compressor Ipm Current Sampling Failure
Compressor Drive Capacitors Precharge
7
Failure
8
Dc Bus Over-Voltage
9
Dc Bus Under-Voltage
10
Ac Input Under-Voltage
11
Ac Input Over-Current
12
Ac Input Voltage Sampling Failure
13
Dsp&Pfc Communication Error
14
Heat Sink Sensor Error
15
Dsp&Mcu Communication Error
16
Abnormal Communication With Main Board
17
Ipm Module Over-Heat
18
Compressor model fault
19
High Pressure Protection
21
Fan1 Fail To Drive
27
Fan1 Over-Current
29
Fan1 1ph Error
35
High pressure switch protection
36
Ow pressure switch protection
37
Klixon protection
38
Inter-boards communication error
39
IPM over current
40
Fail to drive the compressor
41
Compressor over current
42
IPM current sampling failure
43
Heat-sink over-heat
44
Fail to Precharge
45
DC bus over voltage
46
DC bus under voltage
47
AC input under-voltage
48
AC input over-current
49
compressor emergency stop
50
AC input voltage sampling fault
51
Heat-sink sensor error
52
DSP & MCU communication error
Abnormal communication with IDU control
53
board
1ph 3ph
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NIMBUS COMPACT M NET 40 M EXT and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Nimbus compact m net 50 m extNimbus compact m net 70 m extNimbus compact m net 70 m-t ext33009543300955

Table of Contents