Duct positioning

Warning
Consider
Correct duct positi-
oning
Connection
18
Ducts and connectors must be protected and kept closed until the house is ready to be
inhabited.
This is to ensure that no moisture, dirt or dust comes into the ducts, which could create
problems at a later time.
The ducts, which are connected to the unit must have the same diameter as the
connectors or larger.
The dimensions can be seen in the section on technical data.
Duct dimensions and sound absorbers must be in accordance with national standards
and building regulations.
Contact your Dantherm dealer for further information.
Noise and vibrations from the unit to the duct system must be minimised. This can be
achieved by installing sound absorbers on both the supply and exhaust air sides.
See the product description on page 6 and on the labels on the unit to ensure correct
duct positioning.
Connect the duct via nipple (NPU) as shown below
Continued overleaf