Safety Check; Emergency-Stop Switch - Optimum OPTIdrill DP 33 Operating Manual

Table of Contents

Advertisement

1.10

Safety check

Check the drilling machine before each start-up or at least once per shift. Inform the person
responsible immediately of any damage, defects or changes in the operating function.
Check all safety devices
at the beginning of each shift (with the machine stopped),
once a week (with the machine in operation) and
after all maintenance and repair work.
Check that prohibition, warning and information signs and the labels on the drilling machine
are legible (clean them, if necessary)
are complete (replace if necessary).
INFORMATION
Organise the checks according to the following table;
General check
Equipment
Guards
Signs,
Markers
Date:
Functional check
Equipment

Emergency-stop switch

Position switch of protective cover
V-belt
Drill chuck guard position switch
Date:
1.11
Emergency-stop switch
CAUTION!
The drilling spindle keeps turning for a short time even after actuating the emergency
stop switch depending on the preset speed.
1.11.1 Drilling table
Seats for T-slots are attached to the clamping table.
WARNING!
Risk of injury due to workpieces flying off at high speed. Securely fix the workpiece on
the drilling table.
EN
DP33
10
check
Mounted, firmly bolted and not damaged
Installed and legible
Checked by (signature):
check
After the emergency stop button is pressed, the
drilling machine must switch off.
The drilling machine must not be switched on, if the
protective cover of the V-belts is opened.
The drilling machine may not switch on, if the drill
chuck guard is opened.
Checked by (signature):
Translation of original instruction
OK
OK
Safety
Version 1.0.1 - 2020-08-18

Advertisement

Table of Contents
loading

This manual is also suitable for:

3020640

Table of Contents