Altronix ACMCB220 Series Installation Manual

Altronix ACMCB220 Series Installation Manual

Access power controllers with power supplies
Hide thumbs Also See for ACMCB220 Series:

Advertisement

Quick Links

ACMCB220 Series
Access Power Controllers
with Power Supplies
Installation Guide
Models Include:
AL400ACMCB220
- 12VDC @ 4A
or 24VDC @ 3A.
- PTC Protected Outputs
AL600ACMCB220
- 12VDC or 24VDC @ 6A.
- PTC Protected Outputs
Rev. 120115
AL1012ACMCB220
- 12VDC @ 10A.
- PTC Protected Outputs
AL1024ACMCB220
- 24VDC @ 10A.
- PTC Protected Outputs
More than just power.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Altronix ACMCB220 Series

  • Page 1 ACMCB220 Series Access Power Controllers with Power Supplies Installation Guide Models Include: AL400ACMCB220 AL1012ACMCB220 - 12VDC @ 4A - 12VDC @ 10A. or 24VDC @ 3A. - PTC Protected Outputs - PTC Protected Outputs AL600ACMCB220 AL1024ACMCB220 - 12VDC or 24VDC @ 6A.
  • Page 2: Specifications

    Overview: Altronix ACMCB220 Series units distribute and switch power to access control systems and accessories. They convert a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.
  • Page 3: Installation Instructions

    CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 4. Measure voltage before connecting devices. This helps avoiding potential damage. ACMCB220 Series - 3 -...
  • Page 4 [– Control +] and connect power for the locking devices to the terminals marked [– Power +]. When using DC power supplies polarity must be observed. When using AC power supplies polarity need not be observed (Fig. 1d, pg. 6). - 4 - ACMCB220 Series...
  • Page 5: Maintenance

    Fire Alarm Interface trigger input from FACP. Trigger inputs can be normally open, T, + INPUT – normally closed from an FACP output circuit (Fig. 4 through 8, pgs. 8-9). FACP INTERFACE Form “C” relay contact rated @ 1A 28VDC for alarm reporting. NC, C, NO ACMCB220 Series - 5 -...
  • Page 6: Typical Application Diagram

    Battery Status Normal operating condition. Battery fail/low battery. ACM8CB Access Power Controller LED 1 - LED 8 (Red) Output relay(s) energized. Output relay(s) de-energized. Trg (Green) FACP input triggered (alarm condition). FACP normal (non-alarm condition). - 6 - ACMCB220 Series...
  • Page 7 Optional Rechargeable Optional Rechargeable Stand-by Battery Stand-by Battery CAUTION: When power supply board is set for 12VDC use only one (1) 12VDC stand-by battery. Keep power limited wiring separate from non-power limited. Use minimum 0.25" spacing. ACMCB220 Series - 7 -...
  • Page 8: Hookup Diagrams

    Fig. 4 Polarity reversal input from FACP signaling circuit output (polarity is referenced in alarm condition): JUMPER FACP FACP OUTPUT EOL FROM FACP OUTPUT CIRCUIT Fig. 5 Normally Open: Non-Latching FACP trigger input: FACP N.O. TRIGGER INPUT - 8 - ACMCB220 Series...
  • Page 9 N.C. RESET SWITCH JUMPER Fig. 7 Normally Closed: Non-Latching FACP trigger input: FACP N.C. DRY TRIGGER INPUT JUMPER Fig. 8 Normally Closed: Latching FACP trigger input with reset: FACP N.C. RESET SWITCH N.C. TRIGGER JUMPER INPUT ACMCB220 Series - 9 -...
  • Page 10 36AH. You have to reduce either stand-by current consumption or stand-by time in order to comply with requirement. To determine actual battery size please round line [J] to the nearest larger standard battery size. - 10 - ACMCB220 Series...
  • Page 11 Notes: ACMCB220 Series - 11 -...
  • Page 12 (117.22mm) (38.1mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. MEMBER IIACMCB220 Series H21R...

This manual is also suitable for:

Al400acmcb220Al1012acmcb220Al600acmcb220Al1024acmcb220

Table of Contents