3 - Description
Diagram - EVC Control Unit (Std), Diaphragm Liquid System with optional extras
5
1
4
2
3
31
21
20
1. Pump
2. EasyClean filter
3. Suction SmartValve
4. Pressure Regulation Valve (Std/EVC)
5. Pressure SmartValve
6. CycloneFilter
7. Purge Valve
8. Return Line for Boost Function
9. Return pressure drop
10. Return pressure equalization
11. Distribution Valves (EVC)
12. Remote Pressure Gauge
13. Spray Boom
14. Agitation Valve
15. Agitation Tube
16. Return Line / Riser Pipe
20
22
26
26
19
30
16
15
17
18
17
25
14
6
17
7
17
8
24
27
28
17
29
17
Suction lines
Pressure lines
Pressure/Chemical line
17. One-Way Valve
18. Safety Valve
19. Riser Pipe
20. Main Tank Quick Fill coupler
21. Main Tank Quick Fill valve
22. Main Tank Quick Fill hose to tank inlet
23. Flowmeter
24. Rinse Tank (optional)
25. Rinse Tank Quick Fill Coupler (optional)
26. Tank Rinsing Nozzles (optional)
27. Valve block TurboFiller (optional)
28. Turbofiller (optional)
29. Ejector for TurboFiller (optional)
30. Tank tube for TurboFiller (optional)
31. External Cleaning (optional)
12
23
10
9
11
13