Center Section Repair - Graco SaniForce 2150 Repair Parts List Manual

Air-operated high sanitation diaphragm pumps
Hide thumbs Also See for SaniForce 2150:
Table of Contents

Advertisement

Repair
Center Section
Section Repair
Repair
Center
Center
Section
Repair
Tools
Tools
Tools Required
Required
Required
• Torque wrench
• 10 mm socket wrench
• 9/16 in. socket wrench
• Bearing puller
• O-ring pick
• Press, or block and mallet
Disassemble
Disassemble the
Disassemble
the
the Center
Center Section
Center
NOTE:
NOTE: Do not remove undamaged bearings.
NOTE:
1. Follow the
Pressure Relief Procedure, page 9
Remove power from the motor. Disconnect all
hoses.
2. Remove the manifolds and
check valve parts as directed in
Disassemble the Check Valve, page
3. Remove the fluid covers and diaphragms
as directed in
Disassemble the Standard
Diaphragms, page 14
Overmolded Diaphragms, page
NOTE: If you are removing only the diaphragm
shaft bearing (111), skip step 4.
4. Disassemble the air valve as explained in
Air Valve Repair, page 9
5. Use a 9/16 in. socket wrench to remove the
screws (3) and nuts (105) holding the air covers
to the frame.
18
Section
Section
12.
or
Disassemble the
16.
.
6. Use a 10 mm socket wrench to remove the
screws (104) holding the air covers (103) to the
center housing (101).
7. Remove the air cover gaskets (102). Always
replace the gaskets with new ones.
NOTE:
NOTE: If removing the diaphragm shaft bearings
NOTE:
(111), use an o-ring pick to remove the u-cups
(106) first.
8. Use a bearing puller to remove the diaphragm
.
shaft bearings (111), air valve bearings (115)
or pilot pin bearings (113). Do not remove
undamaged bearings.
9. Inspect the u-cups. Replace as needed.