CB1200 Pellet Insert
B. Clearance To Combustibles, UL and ULC
25 in**
25 in**
(635mm)
(635mm)
Figure 9.1
NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protector for
the section under the insert body only. Floor protection to front and sides of insert appliance must be supplied in
addition to this part.
NOTE: Installing as a built-in will require an 811-0680, Rear Shroud (see page section labeled Rear Shroud Assembly
starting on page 21 for details).
WARNING
Fire Risk.
•
Comply with all minimum clearances to
combustibles as specified.
•
Failure to comply may cause house fire.
9
15-1/2 in*
(394mm)
Be sure to follow vent manufacturers clearance
*If interior of chase will be drywalled, add the
thickness to this measurement.
**From finished floor protection. The size of your
floor protector choice must be added to this
dimension. If using Quadra-Fire floor protector,
Part 811-0730, allow 1-1/2 inches (38mm).
7027-804G
29-3/4 in.
(756mm)
to combustibles.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual
design preference.
05/21