BFT GIOTTO BT A 30-60S U Installation And User Manual page 47

Electromechanical control device for vehicular barriers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 40
Logic
Definition
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
1-2
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
TRAFFIC LIGHT
Traffic light pre-
flashing
PREFLASHING
TRAFFIC LIGHT
Steadily lit red light
RED LAMP
ALWAYS ON
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
add 2ch
associates the desired key with the 2nd radio channel command.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Timer command
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
1
 
10
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
11
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
12
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
13
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
14
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Timer command
5
Input configured as Timer command.
0
6
Input configured as Timer Pedestrian command
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
0
Output configured as 2
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
11
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
 
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
11
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
12
output configured as barrier status
0
Pre-flashing switched off.
0
 
1
Red lights flash, for 3 seconds, at start of operation.
0
Red lights off when gate closed.
0
 
1
Red lights on when gate closed.
Optional extras
nd
Radio Channel.
GIOTTO BT A 30-60 S U / GIOTTO BT A 30-60 U -
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Giotto bt a 30-60 u

Table of Contents