BFT ARES Series Installation And User Manual

BFT ARES Series Installation And User Manual

Actuator for rack sliding gates

Advertisement

Quick Links

8
0 2 7 9 0 8
3 6 0 5 6 4
ATTUATORE PER CANCELLI SCORREVOLI A CREMAGLIERA
ACTUATOR FOR RACK SLIDING GATES
ACTIONNEUR POUR PORTAILS COULISSANTS A CREMAILLERE
ANTRIEB FÜR ZAHNSTANGEN-SCHIEBETORE
SERVOMOTOR PARA CANCELAS CORREDERAS DE CREMALLERA
ACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL
Attenzione! Leggere attentamente le "Avvertenze" all'interno! Caution! Read "Warnings" inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l'intérieur!
Achtung! Bitte lesen Sie aufmerksam die „Hinweise" im Inneren! ¡Atención¡ Leer atentamente las "Advertencias" en el interior! Let op! Lees de "Waarschuwingen" aan de binnenkant zorgvuldig!

Advertisement

Table of Contents
loading

Summary of Contents for BFT ARES Series

  • Page 1 0 2 7 9 0 8 3 6 0 5 6 4 ATTUATORE PER CANCELLI SCORREVOLI A CREMAGLIERA ACTUATOR FOR RACK SLIDING GATES ACTIONNEUR POUR PORTAILS COULISSANTS A CREMAILLERE ANTRIEB FÜR ZAHNSTANGEN-SCHIEBETORE SERVOMOTOR PARA CANCELAS CORREDERAS DE CREMALLERA ACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL Attenzione! Leggere attentamente le “Avvertenze”...
  • Page 2 INSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE > 25mm 3x1mm 2x0.75mm 3x1.5mm “X” = Cremagliera, Rack, Crémaillère, Zahnstange, 2x1.5mm Cremallera, Tandheugel RG58 3x1.5mm PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT, Predisposizione fissaggio motore, Preparation for motor mounting, PRÉDISPOSITION DES TUYAUX, VORBEREITUNG DER LEITUNGEN, Aménagement fixation moteur, Vorbereitung Motorbefestigung, DISPOSICIÓN DE TUBOS, VOORBEREIDING LEIDINGEN.
  • Page 3: Power On Led

    0V (-) Display + tasti programmazio ~ (+) Display + programming keys Display + Programmieru ngstasten Pantalla + botones programación Display + programmeringstoetsen 25W max. Connettore scheda opzionale Optional board connector 0V(-) Connecteur carte facultative 24V ~(+) Steckverbinder Zusatzkarte Conector de la tarjeta opcional Connector optionele kaart SCA/2°CH VSAFE ~(-)
  • Page 4 SIMPLIFIED MENU PRESET DEFAULT PARAMETERS Automatic Closing Time language Slow-down speed Opening motor torque Closing motor torque Speed during opening Speed during closing Partial opening Zone Slow-down distance Opening deceleration space 10 Closing deceleration space LOGIC Automatic Closing Time Block Pulses Impulse lock TCA 3 step Pre-alarm...
  • Page 5 ARES -...
  • Page 6 SCHEDA DI ESPANSIONE EXPANSION BOARD CARTE EXPANSION ERWEITERUNGSKARTE TARJETA DE EXPANSIÓN UITBREIDINGSKAART UNIDA Programmeerbare Universele Palmtop Connessione seriale per ante contrapposte, Serial connection for opposite leaves, Connexion série pour vantaux opposés, Serieller Anschluss für einander entgegengesetzte Torflügel, Conexión serial para hojas contrapuestas, Seriële verbinding voor tegenovergestelde vleugels. RX1 (PHOT) BAR2 BAR1...
  • Page 7 FOTOCELLULE PHOTOCELLS PHOTOCELLULES COSTE SAFETY EDGES LINTEAUX FOTOZELLEN FOTOCÉLULAS FOTOCELLEN LEISTEN CANTOS RANDEN 25 24 23 22 21 20 19 18 17 16 15 14 13 12 1-BAR 1-PHOT Bar 1 1-PHOT 1-BAR Bar 1 Bar 1 2-PHOT 2-BAR Bar 2 3-BAR 3-PHOT Bar 1...
  • Page 8 WARNING! Obstacle detection function is vers stat bft . . . not active check photocell connection and/or photocell test error Er01 logic settings...
  • Page 9: General Safety

    INSTALLATION MANUAL WARNING! Important safety instructions. Carefully read and comply with the wires must be left as short as possible. The earthing wire must be the last to Warnings booklet and Instruction booklet that come with the product as incorrect stretch in the case where the cable fixing device becomes loose.
  • Page 10: Terminal Description

    INSTALLATION MANUAL 1) FOREWORD ---------------------------------------------------------- The ARES actuator is highly versatile in terms of installation options due to the 11) TERMINAL BOARD WIRING Fig. F-G extremely low position of the pinion, the actuator’s compact nature and the Once suitable electric cables have been run through the raceways and the auto- height and depth adjustment features it offers.
  • Page 11 INSTALLATION MANUAL 13.4) LANGUAGE MENU (language) At this point, each control panel needs to be configured appropriately, starting by Used to set the programmer’s language on the display. entering a MASTER control panel that will have control over all the others, which therefore have to be set as SLAVE units (see logic menu).
  • Page 12 INSTALLATION MANUAL 13.2) TABLE “B” - LOGIC MENU - (logic) Cross out Logic Default Definition Description setting used Activates automatic closing Automatic Closing Time Excludes automatic closing The Start impulse has no effect during the opening phase. Opening Impulse Ibl open lock The Start impulse becomes effective during the opening phase.
  • Page 13: Sicurezza Generale

    MANUALE D’USO: MANOVRA MANUALE/ USER’S MANUAL: MANOVRA MANUALE/ MANUEL D’UTILISATION: MANOVRA MANUALE/ BE- DIENUNGSANLEITUNG: MANOVRA MANUALE/ MANUEL DE USO: MANOVRA MANUALE/ MANUAL PARA DE USO: MANOVRA MANUALE Fig. 2 (90°) (90°) MANUALE D’USO ( I ) Nel ringraziarVi per la preferenza accordata a questo prodotto, la Ditta è certa che da esso otterrete le prestazioni necessarie al Vostro uso.
  • Page 14: Sécurité Générale

    Cette application n’est pas destinée à être utilisée par des personnes (y USER’S MANUAL (GB) compris les enfants) ayant des capacités mentales, physiques et sensorielles réduites, ni par des personnes dépourvues des connaissances nécessaires, à Thank you for choosing this product. The Firm is confident that its performance will moins d’agir sous la supervision de personnes responsables de leur sécurité...

Table of Contents