17.8) PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access
the programming menus. After 10 consecutive failed attempts to log in, you will
need to wait 3 minutes before trying again. During this time, whenever an attempt
is made to log in, the display will read "BLOC". The default password is 1234.
18) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. K) Refer to specific manual.
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
19) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
(Fig. L)
20) Opposite Barriers
Refer to the U-link instructions for the modules.
NOTE: On the board set as the Slave, the Safety Edge input (Safety Edge/ Test
Safety Edge/ 8k2 Safety Edge) should only be set to SAFE2.
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
180
TCA
1
180
TRF. L GHT. C LR. T
0
240
alar ti e
o p e n . c a l i b .
0
100
(Special par. 1)***
c l o s . c a l i b .
0
100
(Special par. 6)***
accel.
1
10
(Special par. 6)***
0
99
DIST. D ECEL
40
99
OP. F ORCE
40
99
CLS. F ORCE
1
10
BRAKE
15
99
Op. speed
15
99
cl speed
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
(***)=Reference for universal handheld programmer.
TABLE "B" - LOGIC - (LOGIC)
Logic
Definition
Automatic Closing
TCA
44
- GIOTTO BT A 30-60 S U / GIOTTO BT A 30-60 U
INSTALLATION MANUAL
Default
Personal
10
Automatic closing time [s]
Time-to-clear traffic light
40
30
Alarm time
75
Opening value calibration
25
Closing value calibration
3
Deceleration distance [%]
70
Leaf force during opening
75
Leaf force during closing
70
2
99
Speed during opening
99
Speed during closing
Programming number of
operations for maintenance
0
Cross out
Default
setting
used
1
 
Time
21) RESTORING FACTORY SETTINGS (Fig.
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.
- Open the Stop input and press the - and OK keys together (Fig.
- Switch on the board's power (Fig.
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.
- Wait for the procedure to finish (Fig.
- Procedure finished (Fig.
22) PARKING MANAGEMENT SYSTEM CONNECTION
The board has an output for the control of the barrier status configured this
way (Fig. G4).
The logic must be set to AUX3/AUX0=12 .
closed contact between terminals 26-27 with the barrier lowered
open contact between terminals 26-27 with the barrier not lowered.
Definition
Description
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic
zone [s]
light.
If an obstacle is sensed or the photocells are engaged for longer than the set
[s]
time, the AUX contact configured as OPEN GATE ALARM output closes. The
contact is then opened by the Stop command or by the closing limit switch.
Opening value calibration [%]
Set the reference value from 0,0 to 100,0 for the required opening position
(see Paragraph Limit Switch Setting).
Closing value calibration [%]
Set the reference value from 0,0 to 100,0 for the required closing position
(see Paragraph Limit Switch Setting).
Acceleration [%]
Acceleration
Set the acceleration to be applied at the beginning of each movement.
Deceleration distance (switch from running speed to slow-down speed) for
motor(s) both during opening and during closing, given as a percentage
of total travel.
Force exerted by the barrier while opening.
WARNING: It affects impact force directly: make sure that
[%]
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
Force exerted by the barrier while closing.
WARNING: It affects impact force directly: make sure that
[%]
current safety requirements are met with the set value (*).
Install anti-crush safety devices where necessary (**).
Braking [%]
Braking [%]
Set braking to be applied during slow-down phase.
Running speed during opening [%]
Sets the running speed that the barrier must reach during opening, as a
percentage of the maximum speed the actuator can reach.
Running speed during closing [%]
Sets the running speed that the barrier must reach during closing, as a
percentage of the maximum speed the actuator can reach.
Allows you to set a number of operations after which the need for main-
tenance will be reported on the AUX output configured as Maintenance
threshold
or Flashing Light and Maintenance .
[in hundreds]
0
Logic not enabled
1
Switches automatic closing on
M
)
M
ref.1)
M
ref.3)
M
ref.5)
M
ref.6)
Optional extras
M
ref.2)
O
ref.4)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Giotto bt a 30-60 u

Table of Contents