Download Print this page
BFT ARES VELOCE SMART BT A500 Nstallation And User's Manual

BFT ARES VELOCE SMART BT A500 Nstallation And User's Manual

Actuator for rack sliding gates

Advertisement

Quick Links

ACTUATOR FOR RACK SLIDING GATES
Caution! Read "Warnings" inside carefully!

Advertisement

loading

Summary of Contents for BFT ARES VELOCE SMART BT A500

  • Page 1 ACTUATOR FOR RACK SLIDING GATES Caution! Read “Warnings” inside carefully!
  • Page 2 USER’S MANUAL: MANUAL MANOURVE FIG. 3 (180°) (180°) ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 3: Quick Installation

    QUICK INSTALLATION > 25mm 3x1mm 2x0.75mm 3x1.5mm “X”= Rack 2x1.5mm RG58 3x1.5mm EXAMPLE CABLE ARRANGEMENT PREPARATION FOR MOTOR MOUNTING > 10mm MOUNTING THE MOTOR FASTENING LIMIT SWITCH BRACKETS (RH/LH) MOUNTING DRIVE ACCESSORIES ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 4 AUX 3 = 9 AUX 0 = 8 AUX 3 = 10 26 27 50 51 AUX 0 = 9 AUX 0 = 10 26 27 **With reverse logic, opening direction = 000 (DIR=right) ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 5 60 6162 63 6465 70 71 72 737475 76 7778 11 12 13 20 21 27 40 4142 43 50 51 52 The following manoeuvre will be performed at low speed. ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 6 MIN 1 - MAX 3 autoset AUTO OPEN ..AUTO CLOSE Scroll up Scroll down re otes hidden button release desidered button O 01 Con rm/Switch on display Exit Menù ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 7 12 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 8 SAFE 2 = 7 (≥6) THE AUTO-SET MUST BE PERFORMED SEPARATELY ON THE 2 LEAVES BEFORE SETTING THE FUNCTION OF THE OPPOSITE LEAVES. TO CONNECT SEVERAL PHOTOCELLS, REFER TO FIG. T ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 9 2 PHOT / 2 PHOT OP / 2 PHOT CL Bar 1 Bar 1 Bar 2 Bar 2 BAR 8K2 / BAR 8K2 OP / BAR 8K2 CL SAFETY EDGE SAFETY EDGE 8,2Kohm 5% 14 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 10 Open in other direction: 0 DIR= sK Open in other direction: 1 opening direction: left - When switching logic configuration from right to left opening, do not swap over the original connection of terminal JP10. ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 11 Check limit switch and motor connections erf1 Error in setting the SAFE inputs Check the setting of the SAFE inputs is correct ERf3 * X = 0,1,…,9,A,B,C,D,E,F 0--- 10-- 150- 1520 password 24 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 12 INSTALLATION MANUAL 1) GENERAL INFORMATION Usable transmitter versions: The ARES VELOCE SMART BT A500-BT A1000-BT A1000 STEEL actuator is All ROLLING CODE transmitters compatible with highly versatile in terms of installation options due to the extremely low posi- tion of the pinion, the actuator’s compact nature and the height and depth adjustment features it offers.
  • Page 13 The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E, Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage. 26 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 14 (*) Before running the autoset function, make sure you have performed all the assembly and make-safe operations correctly, as set out in the installation warnings in the drive’s manual. ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 15 (*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method. (**) Impact forces can be reduced by using deformable edges. (***) If the calculated value is less than 30 cm, it is set to 30 cm. 28 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 16 Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the movement stops. Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement stops. ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 17 MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with connection). no smart module (fig.R) Identifies board address from 0 to in a local BFT network connection. [ ___ ] Address ADDRESS (see U-LINK OPTIONAL MODULES section) 30 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 18 Red lights flash, for 3 seconds, at start of operation. TRAFFIC LIGHT Red lights off when gate closed. Steadily lit red RED LA P ALWAYS light Red lights on when gate closed. ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 19 ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed. OFF= W LINK programming disabled. 32 - ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL...
  • Page 20 Erreur fin de course toujours actif après le début de la manœuvre Vérifiez connexions fins de course, connexions moteur erf1 erreur de la configuration des entrées SAFE Vérifiez la bonne configuration des entrées SAFE ERf3 * X = 0,1,…,9,A,B,C,D,E,F 0--- 10-- 150- 1520 password ARES VELOCE SMART BT A500/BT A1000/BT A1000 STEEL -...
  • Page 21 www.bftme.ae...

This manual is also suitable for:

Ares veloce smart bt a1000Ares veloce smart bt a1000 steel