Blfc Cleaning - Pentair Fleck 5600 SXT Installer Manual

Hide thumbs Also See for Fleck 5600 SXT:
Table of Contents

Advertisement

9.4.8

BLFC cleaning

1. Using a wrench, remove the BLFC holder (1).
2. Using pliers, remove the cage (4) form the BLCF holder (1).
3. Remove the BLFC washer (3) from the BLFC holder (1).
4. Clean the BLFC washer (3) with a terry cloth.
5. Clean the cage (4).
6. Lubricate the seal (2) with approved lubricant only.
Caution - material
Risk of damage due to wrong lubricant use !
Do not use petroleum-based lubricants such as vaseline, oils, or hydrocarbon-based
lubricants.
Use only approved silicone grease or soapy water !
7. Reverse above procedure steps to rebuild.
Mandatory
The washers (3) have to be installed with their chamfered side upfront the water
stream flow.
Flow indication must be visible after the washer (3) is placed on the holder (1).
Ref. MKT-IM-013 / E - 23.09.2020