System Regeneration Cycle; Downflow Regeneration Cycle (5-Cycles Operation) - Pentair Fleck 5600 SXT Installer Manual

Hide thumbs Also See for Fleck 5600 SXT:
Table of Contents

Advertisement

Installer manual Fleck 5600 SXT - Description
3.5

System regeneration cycle

3.5.1

Downflow regeneration cycle (5-cycles operation)

Service — normal use
Untreated water is directed down through the resin bed and up through the riser tube. The
hardness ions attach themselves to the resin and are removed from the raw water by being
exchanged on the resin beads by sodium ions. The water is conditioned as it passes through the
resin bed.
Backwash — cycle C1
The flow of water is reversed by the valve and directed down the riser tube and up through the
resin bed. During the backwash cycle, the bed is expanded and debris is flushed to the drain, while
the media bed is remixed.
Brine draw & slow rinse — cycles C2
The valve directs water through the brine injector and brine is drawn from the brine tank. The
brine is then directed down through the resin bed and up through the riser tube to the drain. The
hardness ions on the resin beads are replaced by sodium ions and are sent to the drain. The resin
is regenerated during the brine cycle. When the air check valve closes, brine drawing finishes, and
then, the slow rinse phase starts.
Second backwash — cycle C3 (Double backwash units only)
The flow of water is reversed by the valve and directed down the riser tube and up through the
resin bed. During the backwash cycle, the bed is expanded and debris is flushed to the drain, while
the media bed is remixed.
Rapid rinse — cycle C4
The valve directs water down through the resin bed and up through the riser tube to the drain. Any
residual brine is rinsed from the resin bed, while the media bed is re-compacted.
Brine tank refill — cycle C5
Water is directed to the brine tank, at a rate controlled by the refill controller [BLFC], to create
brine for the next regeneration. During brine refill, treated water is already available at the valve
outlet.
Info
For illustration purpose only. Always verify inlet and outlet marking on the valve.
20 / 104
Ref. MKT-IM-013 / E - 23.09.2020

Advertisement

Table of Contents
loading

Table of Contents