Description; Technical Specifications - Pentair Fleck 5600 SXT Installer Manual

Hide thumbs Also See for Fleck 5600 SXT:
Table of Contents

Advertisement

3

Description

3.1

Technical specifications

Design specifications/ratings
Valve body
Rubber components
Valve material certification
Weight (valve with controller)
Recommended operating pressure
Maximum inlet pressure
Hydrostatic test pressure
Water temperature std
Ambient temperature
Flow rates (3.5 bar inlet - valve only)
Continuous service flow (Δp = 1 bar)
Peak service flow (Δp = 1.8 bar)
Cv*
Kv*
Maximum backwash flow
(Δp = 1.8 bar)
*Cv: Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
3
*Kv: Flow rate in m
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank top mounted adapter
Inlet/Outlet
Riser tube
Drain line
Brine line (1650)
Electrical
Power supply
Transformer output voltage
Motor input voltage.
Controller input voltage
Controller max. power consumption
Protection rating
Transient overvoltages
Ref. MKT-IM-013 / E - 23.09.2020
Fiber-reinforced polymer
EP or EPDM
DM174, ACS, CE
2 kg (max)
1.4 - 8.6 bar
8.6 bar
20 bar
1 - 43°C
5 -40°C
3
4.5 m
/h
3
5.9 m
/h
5.2 gpm
3
4.5 m
/h
3
1.6 m
/h
2½"- 8 NPSM
¾" or 1"
26.7 mm O.D., 1.05" tube
½" O.D.
⅜"
230  AC, 50/60 Hz, 15 VA
24 VAC, 10 VA max.
24 VAC
24 VAC
5 W
IP 22
within the limits of category II