Pentair Fleck 5600 SXT Installer Manual page 35

Hide thumbs Also See for Fleck 5600 SXT:
Table of Contents

Advertisement

• the resin volume previously determined;
• the salt amount used per regeneration;
• the volume of water to use for backwash, brine draw, slow rinse and fast rinse.
To calculate the backwash duration:
T
= (N
× BV) / Q
backwash
BVbw
Info
The typical value of the volume of water to be used for backwash is between 1.5 and
4 times the bed volume, depending on the inlet water quality.
To calculate the brine draw duration:
Knowing the injector draw flow rate at the working pressure:
T
= V
/ Q
brine draw
brine
draw
Tip
Multiply the amount of salt in kg by 3 to get a approximation of the brine volume to
draw !
To calculate slow rinse duration:
The volume of water to be used for slow rinse is given in the resin manufacturers specifications.
Generally speaking, it is advised that between 2 and 4 BV of water is used to perform the slow
rinse after brine draw. The slow rinse cycle allows brine to be pushed slowly through the resin
bed, allowing the resin to be in contact with brine for sufficient time and therefore to be
regenerated.
Refer to the injector curve at the common working pressure to determine the slow rinse duration.
T
= (N
x BV) / Q
slow rinse
BVsr
Ref. MKT-IM-013 / E - 23.09.2020
with:
DLFC
T
N
BV: bed volume [L]
Q
with:
T
V
calculation [
Q
with:
SR
T
N
BV: bed volume [L]
Q
Installer manual Fleck 5600 SXT - System sizing
: backwash duration [min]
backwash
: number of bed volume for backwash
BVbw
: drain line flow controller size [L/min]
DLFC
: brine draw duration [min]
brine draw
: brine volume to be drawn [L], see Refill
brine
Page 36].
: injection draw flow rate [L/min]
draw
: slow rinse duration [min]
slow rinse
: number of bed volume for slow rinse
BVsr
: injector slow rinse flow rate [L/min]
SR
35 / 104

Advertisement

Table of Contents
loading

Table of Contents