Installation; Warnings; Safety Notices For Installation; Installation Environement - Pentair Fleck 5600 SXT Installer Manual

Hide thumbs Also See for Fleck 5600 SXT:
Table of Contents

Advertisement

5

Installation

CAUTION
Risk of injury due to electrical shock or pressurized elements !
It is strictly forbidden for not qualified personal, to accede to system's internal parts to
perform any kind of technical action.
Be sure to disconnect the electrical power, close the water inlet and depressurize the
system before opening the front cover to access internal parts !
5.1

Warnings

The manufacturer will not be held liable for any damages to people or properties resulting from
an improper use of the device not compliant with the following instructions.
Whenever this guide doesn't clarify all doubts about installation, service or maintenance, please
contact the technical support of the company that has installed the device.
Device installation must be done by a qualified technician according to the current standards and
regulations, using tools compliant with a device for a safety use and referring to that technician
also for device maintenance.
In case of out of order or malfunction, before performing any kind of action on the device, please
ensure to have disconnected the transformer from the power source, to shut off inlet water supply
to the valve and to drain water pressure opening a tap down-line of the valve.
1.
Be careful when removing the valve from the box and during subsequent handling, weight is
liable to cause damage to property and persons in case of accidental impact.
2.
Before sending the water on the valve, make sure that all plumbing connections are tight and
properly implemented in order to avoid dangerous leaks of pressurized water.
3.
Use caution when installing welded metal piping near the valve, the heat may damage the
plastic body of the valve and the bypass.
4.
Be careful not to let the full weight of the valve on fittings, pipes or bypass.
5.
Make sure that the environment in which the valve is installed does not reach freezing
temperatures of the water, the valve may be damaged.
6.
Make sure that the tank containing the resin is vertical; otherwise the resin could enter in the
valve and damage it.
5.2

Safety notices for installation

• Observe all warnings that appear in this manual;
• only qualified and professional personnel are authorized to carry out installation work.
5.3

Installation environement

5.3.1

General

• Use only brine salts designed for water softening. Do not use ice melt, block, or rock salts;
Ref. MKT-IM-013 / E - 23.09.2020