1 IMPORTANT NOTICE Important bolted connection! Please adhere This operating manual contains various points to the exact recommended torque when and pointers, providing important information tightening this connection. The correct about your new pedelec and how to use it, mounting torque is either displayed on the referring to possible damage to property and the component or listed in the “Bolted connections”...
INTROdUCTION 2 INTRODUCTION 2.1 Overview This part of the operating instructions gives you specific information on how to handle the electrical drive unit components and how to drive a Pedelec. For general information, e. g. for pedelec technology, please refer to the enclosed instructions.
• It is recommended that you only use genu- pedelec before riding it. If the pedelec starts ine BAFANG parts. off suddenly, accidents may occur. • The pedelec may suddenly fall over and • Make sure the pedelec's lights are on before serious injury may occur if nuts and bolts are riding at night.
SAFETY INSTRUCTIONS 3.3 Installation and instructions concerning use of the product by a person responsible for their safety. Maintenance • do not allow children to play near the product. It is vital that all bolted connections on the • Should you encounter any errors or prob- pedelec have the correct torque in order to lems, consult your nearest dealer.
• Natural wear and tear due to normal use Please also consult the additional operating manuals, issued by the individual component and aging is not within our scope of our manufacturers and which were supplied with quality warranty. your pedelec or are available online. Your •...
SAFETY INSTRUCTIONS 3.8 Legal Regulations Before every ride, please check that: • The lights and bell are working and are safely secured. Please stay informed about the national regulations applicable in your specific country. • The brakes are working safely and are prop- erly secured.
4 ELECTRONIC COMPONENTS In order to prevent a malfunction, the following be voided. If non-original or incorrect spare parts instructions should be observed: are used, the pedelec may not function correctly. In the event of a defect, contact an authorized •...
Your Pedelec can be supplied with three different types of batteries. detailed specifications can be found in the table below. Model numbers: BT C01.340.UART, BT C01.450. UART, BT C01.600.UART, BT C01.750.UART Risk of fire or explosion if battery is used with an incompatible system.
4.2.2 Notification A special charger provided by BAFANG must be used to charge these batteries. • The battery should not be left in direct sun- light so as to avoid over-heating, distortion, • do not charge the battery for longer than...
ELECTRONIC COMPONENTS 4.2.3 Caution Avoid charging near exposed flames or in direct sunlight. Do not disassemble the battery. doing so may cause the internal The battery contains protective components protection function to short-circuit and and will internally short-circuit to avoid danger. Mishandling, such as improper disassembly, may lead to abnormal chemical reactions or destroy its protective functions and cause it to...
4.2.4 Specifications Basic settings BT C01.340.UART BT C01.450.UART BT C01.600.UART BT C01.750.UART Power 340 Wh 450 Wh 600 Wh 750 Wh 4.5 h with a 2A 6.5 h with a 2A 5.5 h with a 3A 6.5 h with a 3A...
ELECTRONIC COMPONENTS • When you clean the charger, unplug it from the electrical socket first. • When charging takes longer than shown in the specifications table, stop charging. • After charging, remove the battery from the charger and unplug the charger. 4.4 Hub motor Your Pedelec is equipped with a 250 Watt front-wheel electric motor, which also forms the...
5 OPERATION 5.1 Installing the battery Pull out of rack For correct insertion, the battery must be inserted and locked from the rear of the casing as far as it will go. Without contact with the battery, the electric drive of your pedelec will not work.
OPERATION LED state State of charge Notes When the system is triggered First LEd flickers ≤ 5 % in operation mode: Press the button for 1 second for the BMS to display the charge of One green light 5 < C < 10 % the battery on the LEds for 5 seconds.
Page 16
Errors – Causes and Solutions Error description Cause Solution Check all connections and whether The operating display does Mains plug not properly con- the charger is properly connected to not light up nected to the power supply the power supply The charging indicator is The battery may have a Contact the manufacturer or your...
OPERATION 5.5 Switching the electrical You can switch the electrical system of your Pe- delec on and off according to the description on system on and off the control unit, see section "Control element". If the battery of your Pedelec is equipped with an Make sure that the pedals of your Pedelec are on/off switch, you can also press the switch on not weighed down when the system is turned...
6 DP E08.UART 6.1 Items to be shown on 6.2 Functional overview the Display • The bidirectional serial communication protocol and the keypad with three keys enables users to operate the display with ease. • Intelligent battery level indication: thanks to an optimization algorithm, a stable display of the battery level is ensured, and the prob- lem of fluctuating battery level indications...
dP E08.UART 6.3 Usual operation 6.3.3 Light ON / OFF Press for 2 seconds, LEd display dims, then the front and rear light will be turned on at the 6.3.1 Power ON / OFF same time. Press for 2 seconds, the display will turn ON; Press a second time for 2 seconds, LEd display press...
Page 20
In the Push Assistance mode, the LEd bars light 6.3.5 PAS (Pedal Assist System) level selection up one by one from bottom to top with 0.5 sec- ond time intervals, as shown in the figure below. Assistance level indicator shows the power output of the motor.
dP E08.UART 6.4 Error code definition This system can indicate all errors occurring on the Pedelec. In certain modes, the LEds will flicker when an error code occurs. Error code Error definition Solution The second LEd flickers 7 times in High voltage protection Check the battery voltage rapid succession...
7 DP C13.UART 7.1 Appearance battery level indications common to most displays is avoided. • Level indication: this displays the current assistance level (level 0 to level 5). • Fault code prompt. • Push-assistance. • Light control. 7.4 Items to be shown on the Display 7.2 Specifications and Parameters...
dP C13.UART To change the indicated information, press the Lamp status indication MOdE button to opt for the following: State of charge indication Total range"OdO"(Km) → Trip distance (Km) Riding record → Remaining distance (Km) → Trip Time (Min.) → Motor Power(W)→ Calory(C) → Max Assistance level indication Speed(Km/h) →...
Page 24
7.5.3 Light ON / OFF button 7.5.5 Clearing your Trip Distance • To switch on the display's backlight and the • To clear your trip distance, hold both the headlight of the Pedelec, hold the UP button MOdE and the dOWN button for 2 seconds: for 2 seconds.
dP C13.UART 7.6 Functions Settings • Once the Pedelec system is switched ON, to access the Primary Settings menu, hold both the UP and dOWN buttons for 2 seconds. Never change settings while the Pedelec is in motion. 7.6.1 Unit Conversion "km / mile" Backlight Brightness Settings Interface U represents unit settings 7.6.3...
Page 26
7.6.4 Error Code Indication • To clear the Error Code, hold the UP, dOWN and MOdE buttons simultaneously for 2 seconds. If there are errors pertaining to the electronic control system, the error code will appear automatically. Error Code Memory Interface 7.6.6 Exit settings Error Code Indication...
dP C18.UART 8 DP C18.UART 8.1 Appearance USB charge indication: When external connect into the display, it display the symbol. Headlight indication: Only shows when headlight is on. Speed scale display: the scale value is in accordance with the digital value. Mode selection: single-trip distance (TRIP) →...
8.3 Button definition 8.4 Usual operation Headlight 8.4.1 ON/OFF switch Turn on the power, press and hold (>2S) to power on the display, the display begin to operate. Press and hold (>2S) again ON/OFF to power off the display. If the bike is not used, after 5 minutes (time can be set in down “Auto Off”) the display will be automatically...
Page 29
dP C18.UART 8.4.3 Multiple function interfaces switch Briefly press (0.5s) to switch to different data interface, circularly show signal-trip distance (TRIP) → total distance (OdO) → maximum speed (MAX) → average speed (AVG) → remaining distance (RANGE) → energy consumption (CALORIES) → time (TIME).Energy consumption unit CALORIES means kCal.
Page 30
8.4.4 Headlight/Display Backlight Switch 8.4.5 Push assistance mode Press and hold (>2S) to turn on the Press and hold (>2S) to enter into push display backlight as well as headlight. Press assistance mode, the symbol is displayed, and hold (>2S) again to turn off the when release key , will exit the push as-...
dP C18.UART 8.5 Functions setting • Operating process in the setting interface Unit Brightness Auto Off MAX PAS Power View SOC View Display Setting TRIP Reset AL Sensitivity Password Default Mode Set clock BACK SETTING Wheel Information Speed Llimit Battery info. Error Code EXIT BACK...
Page 32
8.5.1 Enter into “SETTING” interface 8.5.2 Enter into“Display setting”interface After switching on the display, briefly press In “SETTING” interface, briefly press (<0.5S) (<0.5S) for two times to enter into the to select “display setting” and then “SETTING”interface. The interface includes briefly press (<0.5S) to confirm and enter the three options as “display setting”,“Infor...
Page 33
dP C18.UART ⑶ “Auto Off”--- set automatic Off time ⑸ “Power View”--- set output display mode Briefly press (<0.5S) to select Briefly press (<0.5S) to select “Auto Off”, and then briefly press (<0.5S) “Power View”, and then briefly press (<0.5S) .
Page 34
⑹ “SOC View” --- set indication mode for ⑻ “AL Sensitivity” --- set light sensitivity battery capacity Briefly press (<0.5S) to select “AL Briefly press (<0.5S) to selcet “SOC Sensitivity”, and then briefly press (<0.5S) View”, and then briefly press (<0.5S) .
Page 35
dP C18.UART After setting the passwrod, the interface exit back automatically to original interface within two seconds. Briefly press for two times (interval time is less than 0.5S) to exit back to main interface or select “BACK” → “EXIT” to exit back to main interface. Reset password: After setting the password, the interface “Password”...
Page 36
“Wheel” and “Speed . The time is represented in the 24-hour Limit”. User can use BAFANG’s BESST tool system. Cursor stays at the first digit of the to connect the display and PC to modify the clock.
Page 37
dP C18.UART ⑵ “Battery Info.”check Briefly press (<0.5S) to select “Battery Info.” and briefly press (<0.5S) to enter into infor- mation display interface. This moment, select “Nest Page” and briefly press (<0.5S) to switch the display interface. If detecting no data, it display “--”. See the content and corresponding explanation shown in the table below: Display content Explanation...
8.6 Error code definition HMI dP C13.UART and dP C18.UART can indicate all errors occurring on the pedelec. Error Explanation Troubleshooting Brakes enabled Check whether a brake cable is stuck. Bring your Pedelec to your dealer or to a High voltage protection specialist to have the error fixed.
dP C18.UART 8.7 Range of your Pedelec Weather and vehicle weight: In addition to the ambient temperature, wind conditions also influence the range. A strong headwind requires Range data is based on optimal conditions. This more power when driving. Baggage, etc. will can be influenced by the following factors: increase the weight and therefore more force is Level of assistance: The higher the assistance...
9 MAINTENANCE AND REPAIRS 9.2 Battery wear Keep the all components of the electrical system clean. Clean gently with a damp, soft cloth. The components must not be immersed in water or The battery can run for approx. 500 charging. cleaned with a water jet or steam jet.
CUSTOMER SERVICE 10 CUSTOMER SERVICE If you have any questions concerning the electri- cal system, please contact the manufacturer or your specialist dealer. CUSTOMER MANUAL FRONT HUB MOTOR SYSTEM...
11 TRANSPORTING THE PEDELEC 11.3 By airplane Remove the battery before transportation and transport it separately. Cover the contacts with a transport cap to prevent the risk of a short The battery must be considered as a hazard- circuit. In the case of a short circuit, there is a ous material.
dISPOSAL CONSIdERATIONS 12 DISPOSAL CONSIDERATIONS If parts of your Pedelec are replaced, please take According to European directive 2006/66/EC, defective or used batteries must not be used, note of the waste disposal instructions for your and, in accordance with the European directive local waste disposal company.
Brake: Roller-Brake Weight: 2.3 KG Installation Width: 100 mm Max. Housing diameter: 138 mm Cabling Shaft Side: Right Spoke Specification: 13 G Battery Primary Settings BT C01.340.UART BT C01.450.UART BT C01.600.UART BT C01.750.UART Rated voltage 43 dCV 43 dCV 43 dCV...
Page 45
SPECIFICATIONS Primary Settings BT C01.340.UART BT C01.450.UART BT C01.600.UART BT C01.750.UART Consumption rate ≤ 400 uA ≤ 400 uA ≤ 400 uA ≤ 400 uA during sleep Consumption rate 50 uA 50 uA 50 uA 50 uA during sleep Operating tem- perature during 0 –...
14 AFTER-SALES AND WARRANTY POLICY In all nations which apply EU law, the common The BAFANG limited warranty does not cover or conditions for warranty/liability for material apply to the following situations: defects apply. Please inform yourself about the 1. damage, failure and/or loss caused by...
For products no longer case the manufacturer of the pedelec. covered by warranty, BAFANG can still provide For contact details please refer to the war- spare parts or repair the products for customers,...
Page 48
NOTES CUSTOMER MANUAL FRONT HUB MOTOR SYSTEM...
Need help?
Do you have a question about the BT C01.340.UART and is the answer not in the manual?
Questions and answers