Toshiba B-EX Series Operation Manual page 61

Key operation specification
Hide thumbs Also See for B-EX Series:
Table of Contents

Advertisement

Sensor check details
The value of non-installed sensor is unfixed.
SENSOR1 0 0 0 0 0 0 0 0 , 0 0 0 0 0 0 0 0
Thermal head open sensor
1: The head is closed.
(When the print head is unlocked, no printing
performed.)
Thermal head-up sensor
1: The head is lowered.
(When the print head is lifted, no printing performed.)
Cutter home position sensor
0: Home position
1: Outside the home position
Rewinder overflow sensor
0: Normal
1: Overflow
Ribbon take-up motor sensor
0: Outside the slit
1: Inside the slit
Ribbon feed motor sensor
0: Outside the slit
1: Inside the slit
Blank (Fixed to 0)
Strip sensor (Peel-off sensor)
0: Label is not present.
1: Label is present.
(When the strip sensor is not installed, the flag is set to "1".)
Blank (Fixed to 0)
56

Hide quick links:

Advertisement

Table of Contents
loading