Maintenance (Routine And Extraordinary); Control Of Filter Cleaning Condition - Schenker SMART 80 Installation, Use And Maintenance Manual

Digital 12/24 v dc
Table of Contents

Advertisement

6 – MAINTENANCE (ROUTINE AND EXTRAORDINARY)

6. MAINTENANCE (ROUTINE AND EXTRAORDINARY)

6.1 Control of filter cleaning condition

It is very important to inspect filters condition periodically.
The following filters are present in the system:
1. Net filter (strainer)
2. Pump filter (5 micron cartridge filter – white filter housinh)
3. Active carbon filter
follow the instructions given in the table below:
OPERATION
Check and cleaning of
the strainer
Replacing of the 5 micron
cartridge filters
Replace the active
carbon fiber filter
THE PRESENT MANUAL BELONGS TO -
FREQUENCY
Every 5 days
Every 200 working hourse. Once
replaced the filters it is necessary
to purge the air from the system,
opening for 2-3 minutes the
depressurization valve.
Once per year
Schenker Italia
41
COD.
80S12/24.D.2018
PROCEDURE
Visual inspection and washing
Unscrew the filter housing cup
counter clockwise by using the
specific key provided
Unscrew the filter housing cup
counter clockwise by using the
specific key provided
- ALL RIGHTS RESERVED
EN

Advertisement

Table of Contents
loading

Table of Contents