Hydraulic Connections - Schenker SMART 80 Installation, Use And Maintenance Manual

Digital 12/24 v dc
Table of Contents

Advertisement

4 – MOUNTING AND INSTALLATION

4.4 Hydraulic connections

Exhausted
discharge
Plumb
to
pressure
side
of
boat fresh
water
system
Pressurized fresh water valve
Elecrovalve
5 micron filter
Swan neck upward - Disharge
Watermaker
Fresh water outlet
The hydraulic section that is continuously under consistent pressure is the pump outlet – 5 m. filter –
watermaker inlet connections . For this section is necessary to use a good quality PN 16 min. reinforced
hose. An inadequate hose could burst, jeopardizing seriously the safety of the boat.
THE PRESENT MANUAL BELONGS TO -
HYDRAULIC CONNECTION AND PIPES
FIG. 4-1
Schenker Italia
23
COD.
100S12/24.D.2018
"Armovin"
type hose
int. dia. 16
mm.
Pump group
Non return valve
Net filter
Water inlet
Active carbon filter
- ALL RIGHTS RESERVED
EN
"Armovin"
type hose
int. dia. 16 mm.
Reinforced hose
PN16 min int. dia.
16 mm.