3 – PRODUCT PRESENTATION
COD.
80S12/24.D.2018
valve has the function to allow the reset of the ERS in case of a system block. It must be opened before acting
on the valve positioner.
High pressure switch. It Is hydraulically connected with the pump group. It stops the system if the pump
pressure exceeds 13 bar. In this case a high-pressure alarm is activated on the control panel.
Probe (pressure switch). It is a device, hydraulically connected to the left side on the main valve of the Energy
Recovery System. Its function is check that the cycling of the machine is correct. It is set at 1,3 bar.
Computer box. It is an external unit. It has to be installed relatively close to the watermaker, in a position
protected from water. It is connected to the remote panel and controls the functions of the watermaker
automatically.
The microswitches P1and EV allow the direct command of the pump the electrovalve respectively. They can
be used, as an emergency solution, for starting the watermaker in case of total failure of the electronic
computer. In normal condition they have to be switched off.
Emergency
microswitches
Remote panel
Electric
cable connector
connections
COMPUTER BOX WITH SWITCHES
FIG. 3-9