4 – MOUNTING AND INSTALLATION
4.3.3
Fresh water intake for washing
Fresh water
Tee in downstream of the vessel's fresh water
intake for
pressure system.
washing
The following conditions must be respected:
CAUTION
Pressurized tank: Min. flow rate must be 18-20 lit/min. at 2,5 bar.
4.3.4
Brine discharge
The salt-water drain shall be ½'' minimum size
Salt water
discharge
and it has to be preferably above the seawater
level.
Pre-existing salt
It is possible to use offtakes from existing
water discharge
apparatuses, provided that:
(alternatively)
INSTALLATION NOTES
If the discharge is upon the seawater level, it is recommended to provide a valve along the pipe.
CAUTION
Do not run the system when the discharge valve is closed.
THE PRESENT MANUAL BELONGS TO -
•
The flow of the existing fresh water pump
must be min 18 lit/min.
•
Flushing must always be performed with
the pressure water system ON.
•
It is not the engine cooling water drain or
apparatuses that drain out water with
elevated pressure.
Pressurized tank: Min. flow rate
must be 18-20 lit/min. at 2,5 bar.
Schenker Italia
- ALL RIGHTS RESERVED
22
COD.
100S12/24.D.2018
Minimum size ½''