Maintenance (Routine And Special); Check Filter Cleanliness - Schenker SMART 60 Installation, Use And Maintenance Manual

Basic 12/24 v dc
Table of Contents

Advertisement

6 – MAINTENANCE (ROUTINE AND SPECIAL)

6. MAINTENANCE (ROUTINE AND SPECIAL)

6.1 Check filter cleanliness

It is very important to inspect filters condition periodically.
The following filters are present in the system:
1. Mesh filter (strainer)
2. Pump filter (5 micron cartridge filter)
3. Active carbon filter
follow the instructions given in the table below:
OPERATION
Check and cleaning of
the strainer
Replacing of the 5 micron
cartridge filters
Replace the active
carbon fiber filter
THE PRESENT MANUAL BELONGS TO -
FREQUENCY
Every 5 days
It depends on the real working
condition and the turbidity of the
sea water. In average conditions
the replacement of the cartridge is
recommended
every
working hours. Once replaced the
filters it is necessary to purge the
air from the system, opening for 2-
3 minutes the depressurization
valve.
Once per year
Schenker Italia
34
COD: 60S12/24.B.2021
PROCEDURE
Visual inspection and washing
Unscrew the filter housing cup
counter clockwise by using the
specific key provided
100-120
Unscrew the filter housing cup
counter clockwise by using the
specific key provided
- ALL RIGHTS RESERVED