Draft; General; Figure - FLIR E53 User Manual

E series
Hide thumbs Also See for E53:
Table of Contents

Advertisement

30
Application examples

30.5 Draft

30.5.1 General

Draft can be found under baseboards, around door and window casings, and above ceil-
ing trim. This type of draft is often possible to see with an infrared camera, as a cooler air-
stream cools down the surrounding surface.
When you are investigating draft in a house, there should be sub-atmospheric pressure in
the house. Close all doors, windows, and ventilation ducts, and allow the kitchen fan to run
for a while before you take the infrared images.
An infrared image of draft often shows a typical stream pattern. You can see this stream
pattern clearly in the picture below.
Also keep in mind that drafts can be concealed by heat from floor heating circuits.

30.5.2 Figure

The image below shows a ceiling hatch where faulty installation has resulted in a strong
draft.