FLIR E53 User Manual page 127

E series
Hide thumbs Also See for E53:
Table of Contents

Advertisement

27
Technical data
Image presentation modes
Thermal fusion
MSX
Picture in Picture
Gallery
Measurement
Object temperature range
Accuracy
Measurement analysis
Spotmeter
Area
Automatic hot/cold detection
Measurement presets
Difference temperature
Reference temperature
Emissivity correction
Measurement corrections
External optics/windows correction
Screening
Alarm
Color alarm (isotherm)
Measurement function alarm
Set-up
Color palettes
Setup commands
Languages
#T810190; r. AL/47698/47698; en-US
No
Yes
Centered infrared area on the visual image
Yes
–20 to +120°C (–4 to 248°F)
0–650°C (32–1200°F)
±2°C (±3.6°F) or ±2% of reading, for ambient tem-
perature 15–35°C (59–95°F) and object tempera-
ture above 0°C (32°F)
3 in live mode
1 in live mode
Auto-maximum/minimum markers within area
No measurements
Center spot
Hot spot
Cold spot
3 spots
Hot spot–Spot
Yes: as preset (Hot spot–Spot)
Yes: in preview mode
Yes: variable from 0.01 to 1.0 or selected from ma-
terials list
Yes
Yes
0.5°C (0.9°F) accuracy @ 37°C (98.6°F) with
reference
Above
Below
Interval
Condensation (moisture/humidity/dewpoint)
Insulation
Audible/visual alarms (above/below)
Iron
Gray
Rainbow
Arctic
Lava
Rainbow HC
Local adaptation of units, language, date and time
formats