27
Technical data
Image presentation
Screen size
Viewing angle
Color depth (bits)
Aspect ratio
Auto-rotation
Touchscreen
Display technology
Cover glass material
Programmable buttons
Viewfinder
Image adjustment
Image presentation modes
Infrared image
Visual image
Thermal fusion
MSX
Picture in Picture
Gallery
Measurement
Object temperature range
Accuracy
Measurement analysis
Spotmeter
Area
Automatic hot/cold detection
Measurement presets
Difference temperature
Reference temperature
Emissivity correction
Measurement corrections
#T810190; r. AL/47698/47698; en-US
4 in.
80°
24
4:3
Yes
Optically bonded PCAP
IPS
Dragontrail®
1
No
•
Automatic
•
Automatic maximum
•
Automatic minimum
•
Manual
Yes
Yes
No
Yes
Resizable and movable
Yes
•
–20 to +120°C (–4 to 248°F)
•
0–650°C (32–1200°F)
•
300–1500°C (572–2732°F)
±2°C (±3.6°F) or ±2% of reading, for ambient tem-
perature 15–35°C (59–95°F) and object tempera-
ture above 0°C (32°F)
3 in live mode
3 in live mode
Auto-maximum/minimum markers within area
•
No measurements
•
Center spot
•
Hot spot
•
Cold spot
•
User preset 1
•
User preset 2
Yes
Yes
Yes: variable from 0.01 to 1.0 or selected from ma-
terials list
Yes
217