Operation

Cleaning, care and maintenance

4.4.8 Switching frost protection on/off
If you switch on frost protection, the set temperature is automati-
cally set to 7 °C.
If you switch off frost protection, the set temperature is automati-
cally set to 20 °C.
f Keep pressing the mode button until
f
0
the frost protection symbol appears.
Note
f Switch the menu function on using the plus button
f
or off using the minus button and confirm with the
OK button.
4.4.9 Switching rapid heating on/off
Note
You can also switch the function on and off with the rapid
heating button (see chapter "Button functions / Switching
rapid heating on").
f Keep pressing the mode button until
f
0
the rapid heating symbol appears.
Note
f Switch the menu function on using the plus button
f
or off using the minus button and confirm with the
OK button.
5.
Cleaning, care and maintenance
f Never use abrasive or corrosive cleaning agents. A damp
f
cloth is sufficient for cleaning the appliance.
f Check the taps regularly. You can remove limescale deposits
f
at the tap outlets using commercially available descaling
agents.
f Have the electrical safety of the appliance and the func-
f
tion of the safety assembly regularly checked by a heating
contractor.
f Have the protective magnesium anode checked by a heating
f
contractor after the first year. The heating contractor will
then determine the intervals at which it must be checked
thereafter.
f Regularly activate the safety valve to prevent it from becom-
f
ing blocked by limescale deposits.
www.stiebel-eltron.com
6.

Troubleshooting

Problem
Cause
The water does not heat
There is no power.
up and the display does
not light up.
The water does not heat
The set temperature is
up sufficiently and the
set too low.
heat-up symbol lights up.
The appliance heats,
for example, after large
amounts of DHW have
been drawn.
The outlet flow rate is
The aerator in the tap or
low.
shower head is scaled up
or contaminated.
The appliance does not
Key lock is enabled.
respond when a button is
pressed.
The key lock symbol is
flashing.
The display flashes.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000 and 0000-000000):
Remedy
Check the fuse/MCB in
your fuse box/distribu-
tion panel.
Select a higher set tem-
perature.
Wait until the heat-up
symbol goes out again.
Clean and/or descale the
aerator or shower head.
Disable key lock (see
chapter "Settings / Menu
functions / Enabling/
disabling key lock").
Notify your local contrac-
tor. Display the fault code
(see chapter "Settings /
Menu functions / Display-
ing the fault code").
E-NO.: 000000
F-NO.: 0000-000000
PSH Universal EL|
29