OPERATION

Settings

4.
Settings
DHB-E 13 AU
DHB-E 18 AU | DHB-E 27 AU
Should the outlet temperature fail to reach the required level with
the draw-off valve fully open and the temperature selector set to
maximum, then more water is flowing through the appliance than
can be heated by the heating element.
f Reduce the flow rate at the draw-off valve.
f
4.1

Recommended settings

Your instantaneous water heater offers maximum precision and
maximum convenience in DHW provision. Should you nonetheless
be operating the appliance with a thermostatic valve, we recom-
mend that you:
f Set the temperature at the appliance to the maximum tem-
f
perature. Then set the required set temperature on the ther-
mostatic valve.
Saving energy
The following recommended settings will result in the lowest en-
ergy consumption:
- 38 °C for hand washbasins, showers, bath
- 55 °C (50 °C für DHB-E 13 AU) for kitchen sinks
Internal anti-scalding protection (qualified contractors)
If required, the qualified contractor can set a permanent temper-
ature limit, for example in nurseries, hospitals, etc.
Limiting it in this way prevents water from flowing out of the
appliance at temperatures which could cause injury.
Recommended setting for operation with a thermostatic valve
and water preheated by solar energy
f Set the temperature at the appliance to the maximum
f
temperature.
www.stiebel-eltron.com
Following an interruption to the water supply
Material losses
!
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted by taking the following steps.
f Disconnect the appliance from the power supply by
f
removing the fuses/tripping the MCBs.
f Open the tap for one minute until the appliance and
f
its upstream cold water inlet line are free of air.
f Switch the power back ON.
f
5.

Cleaning, care and maintenance

f Never use abrasive or corrosive cleaning agents. A damp
f
cloth is sufficient for cleaning the appliance.
f Check the taps regularly. Limescale deposits at the tap out-
f
lets can be removed using commercially available descaling
agents.