Troubleshooting - STIEBEL ELTRON PSH 30 Universal EL Operation And Installation

Wall mounted water heater with pcb
Hide thumbs Also See for PSH 30 Universal EL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
Installation

Troubleshooting

15. Troubleshooting
Note
The high limit safety cut-out can respond at temperatures
below –15 °C. The appliance may be subjected to these
temperatures during storage or transport.
f Display the fault code (see chapter "Settings / Displaying the
f
fault code").
f The plugs are described in chapter "Specification / Wiring
f
diagrams and connections".
Fault
The heat-up time is very long and the
heat-up symbol lights up.
The safety valve is dripping and the
heat-up symbol does not light up.
The display flashes.
The water does not heat up.
The heat-up symbol does not appear.
The display flashes.
The water does not heat up.
The display flashes.
Reset button, high limit safety cut-out
f Isolate the appliance from the power supply.
f
f Undo the screws and remove the bottom cap.
f
f Disconnect the connecting cable from the electronic assem-
f
bly for operation, position X2.
1 High limit safety cut-out reset button
34
| PSH Universal EL
Code Cause
The flanged immersion heater is scaled up.
The valve seat is contaminated.
The temperature sensor is faulty.
E2
E4
Communication between the electronic assemblies for
E128
control unit and operation is faulty.
The high limit safety cut-out has responded.
E8
The high limit safety cut-out has responded because the
thermostat is faulty.
The high limit safety cut-out has responded because the
temperature has dropped below -15 °C.
The booster heater does not switch on.
The flanged immersion heater is faulty.
The temperature sensor is faulty.
E6
1
Remedy
Descale the flanged immersion heater.
Clean the valve seat.
Check whether plug X10 is properly inserted.
Check the temperature sensor.
Check whether plugs X2 are inserted properly in both
assemblies. Check the assemblies and the connecting
cable.
Check the appliance and eliminate the cause. Press the
reset button (see diagram).
Remedy the cause of the fault. Replace the high limit
safety cut-out.
Press the reset button (see diagram).
Check the button.
Replace the flanged immersion heater.
Check whether plug X10 is properly inserted.
Check the temperature sensor.