Tub pump 230 volt, 50 hz

Advertisement

Voltage:
Voltage at motor must be not more than 10% above or below motor name-
plate rated voltage or motor may overheat, causing overload tripping and re-
duced component life. If voltage is less than 90% or more than 110% of rated
voltage when motor is running at full load, consult power company.
TABLE I - RECOMMENDED WIRING DATA 50 HZ 230V. MOTORS
Model
Motor
No.
H.P.
5JTAC-A
1/2
5JTAD-A
3/4
TABLE II - RECOMMENDED CIRCUIT BREAKER SIZES 50 Hz 230V. MOTORS
Model
Motor
No.
H.P.
5JTAC-A
5JTAD-A
6
Dist in Ft. (M) - Service to Motor
0-100
101-200
(0-30)
(31-60)
14 (2.0)
14 (2.0)
14 (2.0)
14 (2.0)
Full Load
(amps)
1/2
4.0
3/4
4.7
201-300
Temp.
(61-90)
Rating-°C
14 (2.0)
75
14 (2.0)
75
Branch Circuit Breaker
Rating (amps)
15
15