STA-RITE DURA-JET JSACL Owner's Manual
STA-RITE DURA-JET JSACL Owner's Manual

STA-RITE DURA-JET JSACL Owner's Manual

Dura-jet spa pump
Hide thumbs Also See for DURA-JET JSACL:

Advertisement

1/2 HP
3/4 HP
JSACL
JSADL
JSADL-2A
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
North America: 800-752-0183, FAX 800-582-2217
International: 262-728-5551, FAX: 262-728-4461, TELEX: ITT 4970245
www.sta-ritepool.com
Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA
© 2003, Sta-Rite Industries, Inc.
DURA-JET
O
W
N
E
R '
INSTALLATION, OPERATION & PARTS
MODELS
3/4 HP
(2-Speed)
JSAYDL
PUMP
TM
S
M
A
N
1 HP
1 HP
(2-Speed)
JSAEL
JSAYEL
JSAEL-2A
Printed in U.S.A.
U
A
L
1-1/2 HP
JSAFL
JSAEFL
JSAYFL
This manual should be furnished to
the end user of this pump; its use
will reduce service calls and chance
of injury and will lengthen pump life.
S196 (Rev. 1/17/03)

Advertisement

Table of Contents
loading

Summary of Contents for STA-RITE DURA-JET JSACL

  • Page 1 293 Wright Street, Delavan, WI 53115 North America: 800-752-0183, FAX 800-582-2217 International: 262-728-5551, FAX: 262-728-4461, TELEX: ITT 4970245 www.sta-ritepool.com Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA S196 (Rev. 1/17/03) © 2003, Sta-Rite Industries, Inc. Printed in U.S.A.
  • Page 2: Table Of Contents

    To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘JS’ Series Tub Pump: • Is designed to circulate hot water in spas and hot tubs. • Is an excellent performer; durable, reliable.
  • Page 3: Safety Instructions

    • Check all clamps, bolts, lids, and system accessories before testing. • Release all air in system before testing. • Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing. • Water pressure for test must be less than 25 PSI (172 kPa).
  • Page 4: Installation

    INSTALLATION Installation and wiring of pump should only be done by qualified, licensed personnel. Pump mount must: Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Be installed with pump suction inlet below water level at all times (this allows pump to prime).
  • Page 5: Electrical

    ELECTRICAL Ground motor before connecting to electrical power supply! Failure to ground pump motor can cause serious or fatal electrical shock hazard! Do not ground to a gas supply line! To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
  • Page 6 Voltage: Voltage at motor must be not more than 10% above or below motor name- plate rated voltage or motor may overheat, causing overload tripping and re- duced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.
  • Page 7: Operation

    OPERATION Priming Pump: NEVER run pump dry! Running pump dry may damage seals, causing leakage and flooding! Fill pump with water before starting motor. Do not add chemicals to spa system directly in front of pump suction. Adding undiluted chemicals may damage pump and voids warranty. Open gate valves before starting system.
  • Page 8: Pump Service

    PUMP SERVICE Pump should only be serviced by qualified personnel. To avoid dangerous or fatal electrical shock hazard, disconnect power to motor before working on pump or motor! No lubrication or regular maintenance are needed. If shaft seal is damaged, repair as follows: Removing Old Seal: Hazardous voltage.
  • Page 9: Storage/Winterizing

    5. Screw impeller onto shaft until it seats against shaft shoulder. Work slinger over end of impeller sleeve so it rides on sleeve (Figure 6). 6. Remount front plate; using pattern, shown in Figure 7, torque bolts to 30 inch-lbs. (34.5 cm-kg). BE SURE to start with bolt in 3 o’clock position as shown.
  • Page 10 Draining Pump: To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. NOTICE: Do not use anti-freeze solutions (except propylene glycol) in your spa system. Most anti-freezes are hightly toxic and may damage plas- tic components in the system.
  • Page 11: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Read and understand safety and operating instructions in this manual before doing any work on pump! A. PUMP DOES NOT OPERATE 1. Check GFCI for proper operation according to GFCI manufacturer’s in- structions. 2. Check for plugged impeller. Follow disassembly/assembly instructions under “Pump Service”, Page 8.
  • Page 12: Repair Parts List

    REPAIR PARTS LIST DURA-JET SPA PUMP 3/4 through 1-1/2 HP Models 1161 0695 Parts are common to all models listed except as noted; Part Key Nos. 1, Motor; and 8, Impeller, are listed below. Description Qty. Number Motor Chart at Right Model Motor No.
  • Page 16: Warranty

    The foregoing warranties relate to the original consumer pur- chaser (“Purchaser”) only. Sta-Rite shall have the option to re- HRPB, DEPB, System 3, and PL – Tanks ..10 years pair or replace the defective product, at its sole discre- Internal filter components and valves .

Table of Contents