115/230V/60Hz/1Ph TPEA & TPRA Series MODELS
1-1/2 HP
1-1/2 HP
2-1/2 HP
2-1/2 HP
Sta-Rite Pool/Spa Group
293 Wright Street, Delavan, WI 53115
International: 262-728-5551, FAX: 262-728-7550
www.starite.com
Union City, TN • Delavan, WI • Mississauga, ON • Murrieta, CA
© 2006, Sta-Rite Industries
S S T T A
SPA PUMP
O
W
N
E
INSTALLATION, OPERATION & PARTS
1 HP
TPEAE-165L
TPEAF-166L
2 HP
TPEAG-167L
2 HP
TPEAG-167LS
TPEAAG-168L
TPEAAG-168LS
A – – R R I I T T E E
R '
S
M
A
N
TPRAE3-165
TPRAF-174L
TPRAYF-174S
TPRAG-175L
TPEAYG-175L
TPEAAYG-168L
TPEAAYG-168LS
U
A
L
5TPRAYF-156 (50 Hz.)
TPEAYG-167LS
TPEAYG-175LS
This manual should be furnished to
the end user of this pump; its use will
reduce service calls and chance of
injury and will lengthen pump life.
S330 (Rev. 8/22/06)

Advertisement

Table of Contents
loading

Summary of Contents for STA-RITE TPEA Series

  • Page 1 Sta-Rite Pool/Spa Group 293 Wright Street, Delavan, WI 53115 International: 262-728-5551, FAX: 262-728-7550 www.starite.com Union City, TN • Delavan, WI • Mississauga, ON • Murrieta, CA S330 (Rev. 8/22/06) © 2006, Sta-Rite Industries...
  • Page 2: Table Of Contents

    This pump is for use with permanently installed pools and may also be used with hot tubs and • Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque spas if so marked. Do not use with storable pools. A for testing.
  • Page 3: Installation

    P P o o r r t t t t h h r r e e a a d d s s : : Internal - 2" NPT for direct connection to pipe. External - 3" Piping: Buttress. Fits Sta-Rite 38405 - 4094 Union Collar for quick Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if disconnect pipe connection.
  • Page 4: Electrical

    Fittings: ELECTRICAL Fittings restrict flow; for best efficiency use fewest possi- Ground motor before ble fittings. connecting to electrical Avoid fittings which could cause an air trap in suction power supply. Failure to ground motor can cause se- piping. vere or fatal electrical shock Pool and spa drains must conform to International hazard.
  • Page 5 Use Ground Fault Circuit Interrupter (GFCI) as master on- Exactly match supply voltage to motor nameplate off switch; it will sense a short circuit to ground and dis- voltage. Incorrect voltage can cause fire or seri- connect power before it becomes dangerous to pool ously damage motor and voids warranty.
  • Page 6: Operation

    To Wire a Two-Speed Motor OPERA TION Wire the pump as shown in the diagram. N N O O T T I I C C E E : : NEVER run pump dry. Running pump dry may damage seals, causing leakage and flooding. Fill pump Ground (Green) with water before starting motor.
  • Page 7: Pump Service

    Drain all water from pump and piping when expecting PUMP SERVICE freezing temperatures or when storing pump for a long Pump should only be serviced time (see instructions below). by qualified personnel. Keep motor dry and covered during storage. Be sure to prime pump (Pg. 6) To avoid condensation/corrosion problems, d d o o n n o o t t cover before starting.
  • Page 8 7. Remove four screws holding seal plate to motor. 2. If ceramic seat will not locate properly, remove it, place f f a a c c e e u u p p on bench and reclean cavity. Ceramic 8. Place seal plate face down on flat surface and tap out seat should now locate.
  • Page 9: Troubleshooting Guide

    TROUBLESHOOTING E E l l e e c c t t r r i i c c a a l l : : 1. Pump may be running too GUIDE slowly; check voltage at Read and understand safety and operating instruc- motor terminals and at tions in this manual before doing any work on meter while pump is run-...
  • Page 10: Repair Parts List

    For quick disconnect pipe connec- tions, purchase separately Part No. 77703-0105 (2" Slip and 1-1/2" Slip Union Kit) . Kit Includes: 2 #38405-4094 Union Collars 2 #35505-1244 O-Ring 1 #38405-4095 2" Slip Adapter 1 #38405-4096 1-1/2" Slip Adapter REPAIR PARTS LIST 1 through 2-1/2 HP Spa Pumps Part Part...
  • Page 11: Warranty

    • Complete a warranty registration at www.staritepool.com by clicking on “Register Products” and selecting Sta-Rite Pool OR • Complete bottom portion completely and mail within 10 days of installation to Sta-Rite, Attn.: Pool Warranty Dept., 293 Wright St., Delavan , WI 53115 Warranty Registration Card ■...