28 - Bell SAB
This output type activates when an External alarm occurs in the
selected area, and deactivates when area is disarmed or the 'Bell
Duration' timer expires.
29 - Bell SCB
This output type deactivates when an External alarm occurs in the
selected area, and activates when area is disarmed or the 'Bell
Duration' timer expires.
30 - Strobe
This output type activates when an External alarm (or Arm Fail) occurs
in the selected area, and deactivates when area is disarmed (or a valid
User code is entered).
31 - Detector Latch
This output type activates for 5 seconds when the selected area is in
the exit mode then activates again when the area arms and
deactivates when an Intruder alarm occurs or the selected area is
disarmed.
32 - Detector Reset
This output type is normally active, and deactivates for 5 seconds
when the selected area is in the exit mode.
33 - Walk Test Active
This output type activates when the 'Walk Test' procedure is
selected, and deactivates when the 'Walk Test' procedure is
cancelled.
34 - Zones Omitted
This output type activates when a zone in the selected area with the
'Omit' attribute, is omitted by the user, and deactivates when the
zone is reinstated.
35 - 24Hr Zones Omit
This output type activates when a zone programmed as '24Hr Audible'
or '24Hr Silent' (with the 'Omit' attribute) is omitted by the user, and
deactivates when the zone is reinstated.
36 - Reset Required
This output type activates when the selected area requires a reset
following an alarm, and deactivates when the alarm is reset.
37 - Door Strike
This output type activates for the 4 seconds when a User code with the
'Door Strike' attribute is entered for the selected area.
38 - Chime Mimic
This output type activates for 2 seconds when a zone in the selected
area with the 'Chime' attribute is activated.
39 - Chime Enabled
This output type activates when 'Chime' is enabled for the selected
area, and deactivates when 'Chime' is disabled for the selected area.
40 - DK First Knock
This output type activates when a zone in the selected area with the
'Double Knock' attribute is activated for the first time, and deactivates
when the zone causes an alarm or the 'Double Knock Delay' timer
expires.
41 - BP First Knock
This output type activates when a zone in the selected area with the
'Beam Pair' attribute is activated for the first time and deactivates when
another zone with the 'Beam Pair' attribute, causes an alarm or the
'Beam Pair Time' expires.
42 - On Test
This output type activates when a zone in the selected area with the
'Test' attribute is placed on test and deactivates when the 'Soak Test
Time' expires.
43 - Test Fail
This output type activates when a zone in the selected area with the 'Test'
attribute is placed on test (and fails) and deactivates when an Engineer
code is entered or the 'Soak Test Time' expires.
44 - Internal Alarm
This output type activates when an Internal alarm occurs in the selected
area, and deactivates when the alarm is cancelled.
45 - Auto Arming
This output type activates when the selected area 'Auto Arms', and
deactivates when the selected area is disarmed.
INS176-15
46 - Time Arming
This output type activates for 5 minutes prior to the selected area
being armed using the 'Control Timers'.
47 - 1
st
Code Entered
This output type activates for 30 seconds when a User code with the
'Dual Code' attribute is entered for the selected area.
48 - 2
nd
Code Entered
This output type activates for 30 seconds when two User codes with
the 'Dual Code' attribute are entered for the selected area.
49 - Area Secured
This output type activates whenever a 'Security Key' zone type is
used to lock keypads out and deactivates when the keypads are
unlocked again.
50 - Part Armed 1
This output type activates when a Part Arm 1 is selected for the
selected area and deactivates when part arm 1 is disarmed.
51 - Part Armed 2
This output type activates when a Part Arm 2 is selected for the
selected area and deactivates when part arm 2 is disarmed.
52 - Part Armed 3
This output type activates when a Part Arm 3 is selected for the
selected area and deactivates when part arm 3 is disarmed.
53 - Custom Alarm
This output type activates when any 'Custom' zone type causes an
alarm in the selected area and deactivates when a valid user code is
entered.
54 - Zone Warning
This output type activates when 'Custom' zone type in the selected
area with the 'Warning Req' attribute (see page 59 for details) is
activated for the duration of the 'Warning Delay' timer (see page 70
for details) and deactivates when the zone activity is cleared.
55 - Arm Fail Warning
This output type activates when the selected area fails to arm after a
period of time (controlled by the area exit time) when using
'Entry/Exit' or 'Exit Term.' arming and deactivates when the area arms.
56 - Forced Entry
This output type activates for the duration of the 'Forced Entry' timer
(see page 70 for details) when any 'Guard' or 'Custom' zone with the
'Guard' attribute is activated (see page 58 for details),.
57 - Zones Locked Out
This output type activates when any zone is locked out following an
Intruder Alarm activation and deactivates when all zones are clear
and reinstated.
58 - All Areas Armed
This output type activates when all of the selected areas are armed
and deactivates when any one of those areas is disarmed.
59 - Time Arm Disabled
This output type activates when the timed arming procedure is
disabled (see page 59 for details) and deactivates when timed
arming is reinstated.
60 - Armed/Alarm
This output type activates when the selected area is armed and
deactivates when the selected area is disarmed
This output type also pulses when an Intruder alarm occurs in the selected
area, and deactivates when the selected area is disarmed.
61 - Intruder Alarm
This output type activates when an Intruder alarm occurs, and
deactivates when the Intruder alarm is cancelled.
Tamper alarms will not activate this output
62 - Speaker Mimic
This output type activates whenever the internal speaker output is on,
and deactivates when the speaker output is off.
63 - Full Armed/Exit
This output type activates when the selected area is in the full arm exit
mode and then arms and deactivates when the area is disarmed.