Texecom Premier Elite Series Installation Manual page 118

Hide thumbs Also See for Premier Elite Series:
Table of Contents

Advertisement

UDL & Digi Options
Non-Zone Event Types
The default Non-Zone Event codes are as follows:
No
Type
22
Keypad Medical
23
Keypad Fire
24
Keypad Audible PA
25
Keypad Silent PA
26
Duress Code Alarm
27
Alarm Active
28
Bell Active
29
Zones Locked Out
30
Verified Cross Zone Alarm
31
User Code
32
Exit Started
33
Exit Error (Arming Failed)
34
Entry Started
35
Area Arm Suite
36
Armed with Line Fault
37
Open/Close (Full Arm)
38
Open/Close (Part Arm)
39
Auto Open/Close
40
Auto Arm Deferred
41
Open After Alarm (Alarm Abort)
42
Remote Open/Close
43
Quick Arm
44
Recent Closing
45
Reset After Alarm
46
Power Output Fault
47
AC Fail
118
Event
Reporting Group
Alarm
Priority Alarm
Restore
Restore
Alarm
Priority Alarm
Restore
Restore
Alarm
Priority Alarm
Restore
Restore
Alarm
Priority Alarm
Restore
Restore
Alarm
Priority Alarm
Restore
Restore -
Alarm
Not Reported
Restore
Not Reported
Alarm
Not Reported
Restore
Not Reported
Alarm
Alarm
Restore
Alarm
Alarm
Alarm
Restore
Not Reported
Alarm
Not Reported
Restore
Not Reported
Alarm
Not Reported
Restore
Not Reported
Alarm
Open/Close
Restore
Open/Close
Alarm
Not Reported
Restore
Not Reported
Alarm
Open/Close
Restore
Open/Close
Alarm
Not Reported
Restore
Not Reported
Alarm
Open/Close
Restore
Open/Close
Alarm
Open/Close
Restore
Open/Close
Alarm
Open/Close
Restore
Open/Close
Alarm
Open/Close
Restore
Open/Close
Alarm
Open/Close
Restore
Not Reported
Alarm
Open/Close
Restore
Open/Close
Alarm
Not Reported
Restore
Open/Close
Alarm
Open/Close
Restore
Not Reported
Alarm
Restore
Restore
Not Reported
Alarm
Maintenance
Restore
Restore
Alarm
Maintenance
Restore
Restore
Premier Elite Series Installation Manual
Contact ID
SIA
100
MA
100
MH
115
FA
115
FH
120
PA
120
PH
122
PA
122
PH
121
HA
122
HH
-
-
-
-
-
-
-
-
570
BB
570
BU-
130
BV
-
-
-
-
-
-
-
-
-
-
457
EE
457
-
-
-
-
-
-
-
-
-
-
-
-
-
401
OP
401
CL
401
OP
401
CL
403
OA
403
CA
405
CE
-
-
406
OR
-
-
407
OP
407
CL
-
-
408
CL
459
CR
-
-
-
-
-
-
300
YP
300
YQ
301
AT
301
AR
ID
Keypad No *
Keypad No *
Keypad No *
Keypad No *
Keypad No *
Keypad No *
Keypad No *
Keypad No *
User No
User No
-
-
-
-
Zone No
Zone No-
00
-
User No
-
Keypad No
-
00
00-
-
-
Suite No 1 - 8
-
User No
-
User No
User No
User No
User No
00
00
User No
-
00
-
00
00
-
Keypad No *
00
-
Reset ID ****
-
Device ID **
Device ID **
00
00
INS176-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents