Texecom Premier Elite Series Installation Manual page 21

Hide thumbs Also See for Premier Elite Series:
Table of Contents

Advertisement

Premier Elite Series Installation Manual
LED Network Diagnostics
Each network has two LED's to indicate data flow. The red LED indicates data flowing out of the 'T' terminal and the green LED indicates data
flowing into the 'R' terminal. The table below shows each LED status and its meaning:
Elite Panel
On
TX (Red)
Normal Operation
RX (Green)
Cable Short to 0v
8XP
NETWORK IN
NETWORK OUT
+ -
+ -
T
R
T
R
Remote
A
B
C
Power
ON
1
2 3 4
8/32XP-w
On
RX
Normal Operation
TX
Fault
1
2
3
4
5
6
YPE0123456
OUTPUTS
RKP
On
RX
Normal Operation
iProx
On
RX
Normal Operation
The LED's are provided as an aid for fault finding and therefore should not be completely relied upon to indicate that there is a fault.
INS176-15
Flashing
Panel Fault
Normal operation when device is connected
On
LED A
N/A
Tamper
Disable
LED B
N/A
LED C
Expander Online
Flashing
Fault
Normal Operation
7
8
Off
No connection on 'T' wire
Off
No connection on 'T' wire
Off
Cable short to 12v
No devices connected or short to 12v
Flashing
Data pulses from Panel
Data pulses from devices on Network Out
Flashes address number when in Engineering
/ all expanders flash as one until first
connected
Off
No connection on 'T' wire
No connection on 'T' wire / Incorrectly addressed
Installation
Off
No connection
Network Out not Connected
No power
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents