Specifications
Standby and Recharge Times
EN50131-1
Minimum Standby Period
Maximum Recharge Time
PD6662
Standby Period
Maximum Recharge Time
Power Supply
Rated Input:
Rated Output Current @ 55°C::
Rated Output Voltage:
Mains Terminal Block Fuse:
Maximum rating of each power output (note that these are not considered to be
"independent power outputs" according to EN50131-6
Standby Current
Output Voltage Range:
Maximum Ripple Voltage:
Battery type:
Battery Low Voltage Signal:
Power Output Fault signal:
Deep Discharge protection:
Over voltage protection trigger:
Fuses
Panel
24/48 & 64-W
Housing
3mm Polycarbonate
Dimensions (W x H x D)
305mm
98mm
Battery Compartment
One 12V 7.0Ah battery
Packed Weight
1.7 Kg (Approx)
Premier Elite 48/88/168
Current
Current Consumption
Maximum Current Available
0.75A charge
0.3A charge
Rated Output
Battery
Battery
Arrangement
Charge
1 x 7Ah
0.3A
0.458A
0.3A
1.29A
1 x 17Ah
0.75A
1.0A
Standby and Recharge Times
EN50131-1
Grade 1
Minimum Standby Period
Maximum Recharge Time
72 Hrs
PD6662
Grade 1
Standby Period
12 Hrs
Maximum Recharge Time
72 Hrs
*30h if MAINS FAIL is reported to ARC, otherwise 60h
**This time may be halved if mains failure is signalled to an ARC
Jumper Settings
Recharge
Battery Arrangement
Time
1 x 7Ah
< 24Hrs
< 24Hrs
1 x 17Ah
< 72Hrs
Power Supply
Rated Input:
Rated Output Current@40°C:
Rated Input:
Rated Output Current@40°C:
Rated Output Voltage:
Mains Terminal Block Fuse:
Maximum rating of each power output (note that these are not considered to be
"independent power outputs" according to EN50131-6
Standby Current
146
Grade 1
Grade 2
12h
12h
72 Hrs
72 Hrs
Grade 1
Grade 2
12 Hrs
12 Hrs
72 Hrs
72 Hrs
Type A
100V - 240V @ 50/60Hz; 1A
1.5A MAX
13.&Vdc +/- 2%
250Vac; 3-3.15A Slow/Medium Blow
Aux 12V
1.0A
Bell/Strobe
1.0A
Network 1
1.0A
Battery
1.6A
DC+/DC-
1.0A
150mA
13.0V to 13.9V
0.5V pk-pk
sealed lead acid, up to 7Ah, Maximum
recharge time 72h
9.5V
10.5V (with mains present)
8.1V
16V
F6 PTC (0.9A) Auxiliary 12V Power
fuse
F4 PTC (0.9 A) Network 1 fuse
F5 PTC (0.9 A) Bell/Strobe fuse
12-W
3mm Polycarbonate
x
263mm
x
283mm x 229mm x
85mm
One 12V 7.0Ah battery
1.7 Kg (Approx)
125mA
1.0A
1.9A
Rated Output (Amps)
12h
24h
30h
0.166A
0.108A
0.583A
0.441A
0.158A
0.583A
0.441A
0.1588A
Grade 2
Grade 3
12h
12h
30h *
72 Hrs
24 Hrs
Grade 2
Grade 3
12 Hrs
24 Hrs **
72 Hrs
24 Hrs
Battery Charge Selector
0.3 A
0.75 A
0.3 A
Type A
220V - 240V @50/60Hz; 1A
2.5A MAX
100VV - 120V @50/60Hz; 1A
2.3A MAX
13.&Vdc +/- 2%
250Vac; 3-3.15A Slow/Medium Blow
Aux 12V
1.0A
Bell/Strobe
1.0A
Network 1 & 2
1.0A
Battery
1.6A
DC+/DC-
1.0A
125mA
Output Voltage Range:
Maximum Ripple Voltage:
Battery type:
Battery Low Voltage Signal:
Power Output Fault signal:
Deep Discharge protection:
Over voltage protection trigger:
Fuses
Housing
Dimensions (W x H x D)
Battery Compartment
Packed Weight
Premier Elite 640
Current
Current Consumption
Maximum Current Available
0.75A charge
Rated Output
Battery
Arrangement
1 x 17Ah
Standby and Recharge Times
EN50131-1
Minimum Standby Period
Maximum Recharge Time
PD6662
Standby Period
Maximum Recharge Time
*30h if MAINS FAIL is reported to ARC, otherwise 60h
**This time may be halved if mains failure is signalled to an ARC
Power Supply
Rated Input:
Rated Output Current@40°C:
Rated Input:
Rated Output Current@40°C:
Rated Output Voltage:
Mains Terminal Block Fuse:
Maximum rating of each power output (note that these are not considered to be
"independent power outputs" according to EN50131-6
60h
Standby Current
Output Voltage Range:
Maximum Ripple Voltage:
Battery type:
Battery Low Voltage Signal:
Power Output Fault signal:
Deep Discharge protection:
Over voltage protection trigger:
Fuses (Electronic PTC)
Housing
Dimensions (W x H x D)
Battery Compartment
Packed Weight
General (All Models)
Data Network
Remote Keypads
12-W
24 &48 & 48/64-W
Premier Elite Series Installation Manual
13.0V to 13.9V
0.5V pk-pk
sealed
lead
Maximum recharge time 72h
9.5V
10.5V (with mains present)
8.6V
16V
F1 (1Amp) Auxiliary 12V Power fuse
F2 (1.6 Amp) Battery fuse (electronic
PTC)
F3 (1 Amp) Network 1 fuse
F4 (1 Amp) Bell/Strobe fuse
F5 (1 Amp) Network 2 fuse (168 only)
1mm Mild Steel
315mm x 415mm x 100mm
Up tp one 18Ah battery
4.5 Kg (Approx)
125mA
1.0A
Rated Output (Amps)
Battery
Charge
12h
24h
0.75A
1.0A
0.558A
Grade 1
Grade 2
12h
12h
72 Hrs
72 Hrs
Grade 1
Grade 2
12 Hrs
12 Hrs
72 Hrs
72 Hrs
Type A
220V - 240V @50/60Hz; 1A
2.5A MAX
100VV - 120V @50/60Hz; 1A
2.3A MAX
13.&Vdc +/- 2%
250Vac; 3-3.15A Slow/Medium Blow
Aux 12V
Bell/Strobe
Network 1 & 2
Battery
DC+/DC-
150mA
13.0V to 13.9V
0.5V pk-pk
sealed
lead
Maximum recharge time 72h
9.5V
10.5V (with mains present)
8.6V
16V
F3 (1600 mA) Battery
F4 (250mA) Speaker
F5 (900mA) Network 1
F6 (900mA) Bell/Strobe
F7 (900mA) Network 2
F8 (900mA) Network 3
F9 (900mA) Network 4
F10 (900mA) Network 5
F11 (900mA) Network 6
F12 (900mA) Network 7
F13 (900mA) Network 8
F14 (900mA) Auxiliary 12V
1mm Mild Steel
315mm x 415mm x 100mm
Up tp one 18Ah battery
4.5 Kg (Approx)
4-wire standard 7/0.2 alarm
cable up to 500m Star, Daisy
Chain or any combination of the
two
Up to 2
Up to 4
acid,
up
to
18Ah,
30h
60h
0.416A
0.133A
Grade 3
30h *
24 Hrs
Grade 3
24 Hrs **
24 Hrs
1.0A
1.0A
1.0A
1.6A
1.0A
acid,
up
to
18Ah,