Installation
Switch 3 ON = Impaq Contact-W Wired Input 2 will report as Tamper
(default)
OFF = input 2 will report as an Alarm.
Switch 4 OFF Walk test
19: Ricochet Eng keypad connection (not 12-W)
An engineer's keypad (LCD keypad and interface lead) can be
temporarily
plugged
onto
this
connector
to
allow
system
programming and testing. Set the keypad address switches to all
ON.
20: Ricochet Firmware Flash Port
Connections for flasher interface to update Ricochet receiver
firmware.(Factory use only)
21: Commission Mode Jumper
Fit when learning and placing devices, remove once complete.
22: Antenna
RF antenna
23: RF LED's
Left = RED Transmit, Middle = GREEN Receive, Right = RED
Wireless Network Tick.
24: Plug-on Communicator Connections
This socket provides connection for COM300/COM2400 plug-on
communicators via the lead provided.
25: Ricochet Comm. Port Connection
Serial communications port for connecting to a PC via PC Com/USB
Com or Com IP for use with Ricochet Monitor Software.
26: Cover Tamper
Provides tamper protection for the control panel.
27: Heartbeat LED/Power Light
Flashes steadily to indicate that the control panel is functioning
correctly. If the light is ON or OFF all the time, then there could be a
problem.
28: Cover Tamper Disable
Disables the lid tamper
29: Flash Programming Port
For upgrading the panel firmware.
30: Battery Charge Selection
Select .03A or 0.75A battery charging current
31: Current Reading Pads
To calculate the current draw of the control panel, measure the
voltage across the two pads and multiply by 10 i.e. Reading = 34mV
(x10) = 340mV = 340mA.
32: Battery Kick-start Button
When powering up the panel without AC Mains present, this button
must be pressed in order to connect the battery. If AC Mains is
present this button does not need to be pressed.
33: Power Supply Connection
Only for use with the Texecom PSU.
DO NOT CONNECT ANY OTHER MAINS SUPPLY TO THESE
TERMINALS
PTC Protection Fuses
The following fuses are provided:
F6 PTC (0.9A) Auxiliary 12V Power fuse
F4 PTC (0.9 A) Network 1 fuse
F5 PTC (0.9 A) Bell/Strobe fuse
INS176-15