Area Programming
If the selected area is fully armed and an Intruder alarm occurs in
that area, Intruder alarm events (for that area) are reported to the
Alarm Receiving Centre after any programmed 'Digi delay' has
expired
Areas not assigned to 'Full Arm Coms' will never report Intruder alarm
events to the Alarm Receiving Centre when they are fully armed.
19 - Part Arm Coms
Areas assigned to 'Part Arm Coms' will respond as follows:
If an assigned area is part armed and an Intruder alarm occurs in
that area, Intruder alarm events (for that area) are reported to the
Alarm Receiving Centre after any programmed 'Digi delay' has
expired
Areas not assigned to 'Part Arm Coms' will never report Intruder alarm
events to the Alarm Receiving Centre when the area is Part armed.
20 - Unarm Fire Coms
Areas assigned to 'Unarm Fire Coms' will respond as follows:
If an assigned area is unarmed and a Fire alarm occurs in that
area, Fire alarm events (for that area) will be reported to the Alarm
Receiving Centre
Areas not assigned to 'Unarm Fire Coms' will never report Fire alarm
events to the Alarm Receiving Centre when the area is unarmed.
Fire alarm events are always reported to the Alarm Receiving
Centre when the area is armed regardless of whether the area
is assigned to this option or not.
21 - Unarm Tamp. Coms
Areas assigned to 'Unarm Tamp. Coms' will respond as follows:
If an assigned area is unarmed and a 24Hr or Tamper alarm or
reportable fault occurs in that area, the event will be reported to
the Alarm Receiving Centre
Areas not assigned to 'Unarm Tamp. Coms' will never report 24Hr or
Tamper alarm events or faults to the Alarm Receiving Centre when
the area is unarmed.
24Hr and Tamper alarm events are always reported to the
Alarm Receiving Centre when the area is armed regardless of
whether the area is assigned to this option or not.
22 - Auto Arm Areas
Areas assigned to 'Auto Arm Areas' will respond as follows:
When an assigned area is disarmed, the 'Auto Arm Delay' timer
will start (see page 69 for details)
Every time a detector in that area is activated, the timer is
restarted
If the timer is allowed to expire i.e. no detectors in the assigned
area are activated, the area will arm itself
Areas not assigned to 'Auto Arm Areas' will never try to arm
themselves.
23 - Area A Foyer
Area A can be used as a common area (automatically arms last and
disarms first). Areas assigned to 'Area A Foyer' will cause the panel
to respond as follows:
When all assigned areas are armed, Area A will automatically
arm itself
When any one assigned area is disarmed, Area A will
automatically disarm itself
Areas not assigned to 'Area A Foyer' will not affect the automatic
arming of area A.
24 - Log Part Omits
Areas assigned to 'Log Part Omits' respond as follows:
When an assigned area is part armed, all the zones that are
omitted for that area are logged in the event log
Areas not assigned to 'Log Part Omit' will never log the zones that are
omitted in the event log when the area is part armed.
25 - Multi Knock Area
Areas assigned to 'Multi Knock Area' will respond as follows:
66
Premier Elite Series Installation Manual
Zones with the 'Double Knock' attribute will use the multiple
knock value set up in system options for zone activations (see
page 74 for details)
Areas not assigned to 'Multi Knock Area' will use the standard 2
knocks for zone activations.
For the 'Multi Knock Area' feature to work, the zone must be
programmed with the 'Double Knock' attribute (see page 58 for
details).
26 - UDL Keypad
Areas assigned to 'UDL Keypad' can be controlled i.e. armed,
disarmed, reset etc. from the 'On Line Keypad' when using the
Wintex software and a PC.
Areas not assigned to 'UDL Keypad' cannot be controlled i.e. armed,
disarmed, reset etc. from the 'On Line Keypad' when using the
Wintex software and a PC.
27 - Auto Chime (C2A)
Areas assigned to 'Auto Chime' will respond as follows:
Zones assigned to the selected areas that have been
programmed for 'Chime' will only chime when 'Custom Output
2, Stage A' is on
Areas not assigned to 'Auto Chime' will only chime when chime for
that area is manually enabled by the user.
DD 243 Options
To comply with DD 243, during the normal entry delay, the control
panel must prevent a Confirmed Intruder Alarm from being reported
to the Alarm Receiving Centre.
If a Portable ACE i.e. Electronic Keyswitch, Key Fob, Tag, Swipe Card etc
is being used for disarming, it is permissible for the Confirmed Intruder
Alarm signal to be re-enabled after the entry delay has expired.
The following two options have been provided to ensure that the
control panel can be programmed to comply with this standard if
required.
WARNING
Owing to the ability to disable ALL of the
confirmation facilities, the customer should be
advised in writing by the alarm company that ALL
means of alarm confirmation are disabled when the
initial entry door is opened. The alarm company
should then obtain written acceptance from the
customer of the disabling of the means of alarm
confirmation.
28 - Confirm in Entry
Areas assigned to 'Confirm in Entry' will respond as follows:
If the entry mode is started for the selected area and a Confirmed
Intruder alarm occurs in that area, Confirmed Intruder alarm events
(for that area) are reported to the Alarm Receiving Centre
Areas not assigned to 'Confirm in Entry' will never report Confirmed
Intruder alarm events to the Alarm Receiving Centre during the entry
mode.
To comply with DD 243, areas must NOT be assigned to this
option, thus preventing Confirmed Intruder Alarms from being
reported to the Alarm Receiving Centre during the entry
mode.
29 - Conf. after Entry
Areas assigned to 'Conf. After Entry' will respond as follows:
Alarm confirmation is ONLY disabled for the duration of the Entry
Time and is RE-ENABLED once the Entry Time has expired, after
which activation of a further two zones that are not on the entry route
must occur before the Alarm Confirmation output will activate
INS176-15