Texecom Premier Elite Series Installation Manual page 73

Hide thumbs Also See for Premier Elite Series:
Table of Contents

Advertisement

Premier Elite Series Installation Manual
No Soak Test Warn
If zones have been placed on Soak Test, no warning will be shown to
the user at the time of arming.
44 – FOB Batt Warn
When during arming if a low fob battery event is received the arming
will be cancelled and the keypad will generate a warning, the user
will have to affirm the "Arm with faults" on the keypad before arming
will proceed. Both the low battery and the user acknowledgement will
be logged.
No FOB Batt Warn
When during arming if a low fob battery event is received the arming
will proceed but the low fob battery will be logged in the event log.
45 – Entry Stray
Enables Entry Stray to comply with BS8243 or EN50131-1. This flag
is selectable by configuring option 46.
No Entry Stray
Disables Entry Stray
46 – BS Entry Stray
A second alarm condition during the alarm notification period will
immediately expire the alarm notification timer. This will cause a
confirmed alarm message to be set to the arc and logged in the
event log.
No BS Entry Stray
Second and subsequent alarm conditions during the alarm
notification period have no effect on the timer.
47 – Tamp No Confirm
If a device has caused an unconfirmed alarm then a tamper from that
same device will not cause a confirmed alarm.
Tamper Confirm
If a device has caused an unconfirmed alarm then a tamper from that
same device will cause a confirmed alarm.
48 – Radio 2 Step Arm
When arming using a wireless FOB. The arming procedure requires
two steps.
Radio 1 Step Arm
When arming using a wireless FOB. The arming procedure requires
one step.
49 - Radio Step 2 Zone
When configuration option 48 is programmed as 'Radio 2 Step Arm'
the second step of the arming procedure is the activation of any zone
programmed as 'Guard Access'.
Radio Step 2 RKP
When configuration option 48 is programmed as 'Radio 2 Step Arm'
the second step of the arming procedure is confirmation via the
keypad
50 – Conf Hold Up EN
Once a PA zone is activated the hold-up timer is started (See Global
System Timers for Confirmed PA Timer), the confirmed alarm will
generate if one of the following happens, another PA Zone activated
or a tamper from a device, multi-action PA or a global tamper within
the timer period.
No Conf Hold Up
No confirmed hold-up will be generated.
51 – Max Log msgs 3
Log events from individual sources are limited to 3.
No Max Log msgs
Log events from individual sources are not limited to 3.
52 – Code Entry Timed
When 10 failed code attempts have been made, the keypad will lock
out for 90 seconds. If the panel is grade 2 a further 10 failed code
entry attempts the will keypad will locked out for 90 seconds. If the
panel is grade 3 then after every single failed code entry attempt the
keypad will lock out for 90 seconds. After 21 failed code entry
attempts the code tamper alarm is generated and logged.
No code Ent Time
Failed code entry attempts will not lock out keypads or generate a
code tamper
INS176-15
53 – Enable PD6662:2010
The panel will be defaulted to operate according to PD6662:2010
Disable PD6662:2010
The panel will operate according to the requirements of PD6662:2004
54 - Aux Input = Tamper
will log and report a Tamper from the Aux input.
Aux Input = Fault
will report and log a Aux Fault from the Aux input.
55 - Bell Squawk on Part Arm
the bell will squawk when the system is part armed.
No Bell Squawk on Part Arm
the bell will not squawk when the system is part armed.
56 - Do not Display Open Zones
Open or active zones will not be displayed on the relevant keypads.
Display Open Zones
Open or active zones will be displayed on the relevant keypads.
57 - Do not Enable Battery Replacement Mode
User 01 with the Master User type will not have access to a new
option in the user menu "Start Battery Replacement".
Enable Battery Replacement Mode
User 01 with the Master User type will have access to a new option in
the user menu "Start Battery Replacement".
58– Remote Arming Instant
Remote arming from a PC through Wintex, or mobile apps will be
instant.
Remote Arming Timed
Remote arming will be timed and use the Exit Time programmed for
the area being armed. This option should be chosen to comply with
IA1501 & PD6662.
Global Options
73