These options control how various features affect each area. Any
number of areas can be assigned to each option.
00 - Auto Part Arm
Areas assigned to 'Auto Part Arm' will fully arm if an 'Entry/Exit' zone
is activated during the exit mode and will 'Part Arm 1' if an 'Entry/Exit'
zone is not activated during the exit mode.
Areas not assigned to 'Auto Part' will always fully arm.
1 - Part Arm Instant
Areas assigned to 'Part Arm Instant' will arm instantly when part
arming.
Areas not assigned to 'Part Arm Instant' will use the area exit timer
when part arming.
2 - Part Arm Silent
Areas assigned to 'Part Arm Silent' will never generate Exit tones
when part arming.
Areas not assigned to 'Part Arm Silent' will always generate Exit
tones when part arming.
3 - Remote Arm
Areas assigned to 'Remote Arm' can be armed remotely using the
Wintex UDL software and a PC.
Areas not assigned cannot be armed remotely.
4 - Remote Disarm
Areas assigned to 'Remote Disarm' can be disarmed remotely using
the Wintex UDL software and a PC.
Areas not assigned to 'Remote Arming' cannot be disarmed
remotely.
5 - Panel Tamper
Areas assigned to 'Panel Tamper' will cause a Tamper alarm when
the control panel cover is removed.
Areas not assigned to 'Panel Tamper' will never cause a Tamper
alarm when the control panel cover is removed.
6 - Bell Tamper
Areas assigned to 'Bell Tamper' will cause a Tamper alarm when the
Bell tamper loop is broken.
Areas not assigned to 'Bell Tamper' will never cause a Tamper alarm
when the bell tamper loop is broken.
7 - Auxiliary Tamper
Areas assigned to 'Auxiliary Tamper' will cause a Tamper alarm when
the Auxiliary tamper loop is broken.
Areas not assigned to 'Auxiliary Tamper' will never cause a Tamper alarm
when the auxiliary tamper loop is broken.
8 - Panel Speaker
Areas assigned to 'Panel Speaker' will cause the control panel
speaker to activate when those areas are in alarm, entry and exit etc.
Areas not assigned to 'Panel Speaker' will never cause the control panel
speaker to activate when those areas are in alarm, entry and exit etc.
9 - Bell & Strobe op
Areas assigned to 'Bell & Strobe op' will cause the 'Bell/Strobe'
output on the control panel to activate when an alarm occurs in those
areas.
Areas not assigned to 'Bell & Strobe op' will never cause the
'Bell/Strobe' output on the control panel to activate when an alarm
occurs in those areas.
10 - Alarms Eng Reset
Each area can be programmed for Engineer or User reset following
an Intruder alarm. Areas Assigned to 'Alarms Eng Reset' will respond
as follows:
The assigned areas can only be reset using an Engineer code
If 'Anti-code Reset' is enabled (option 13) the assigned areas
can also be reset using the Anti-code
Areas not assigned to 'Alarms Eng Reset' can be reset with any User
code that is valid for those areas.
11 - Confirmed Reset
Each area can be programmed for Engineer or User reset following a
Confirmed alarm. Areas Assigned to 'Confirmed Reset' will respond
as follows:
The assigned areas can only be reset using an Engineer code
INS176-15
If 'Anti-code Reset' is enabled (option 13) the assigned areas
can also be reset using the Anti-code
Areas not assigned to 'Confirmed Reset' can only be reset with any
User code that is valid for those areas providing that 'Alarms Eng
Reset' (option 13) is also programmed for user reset.
12 - Tamper Eng Reset
Each area can be programmed for Engineer or User reset following a
Tamper alarm (when the area is unarmed). Areas assigned to 'Tamper
Eng Reset' will respond as follows:
The assigned areas can only be reset using an Engineer code
If 'Anti-code Reset' is enabled (option 13) the assigned areas
can also be reset using the Anti-code
Areas not assigned to 'Tamper Eng Reset' can be reset with any User
code that is valid for those areas.
13 - Anti-code Reset
Each area can be programmed for Anti-code Reset following an
Intruder or Tamper alarm. Areas assigned to 'Anti-code Reset' will
respond as follows:
The assigned areas can be reset using the Anti-code as well as
an Engineer code
Areas not assigned to 'Anti-code Reset' can only be reset using an
Engineer code or User code.
Areas can only be assigned to 'Anti-code Reset' if they are
also assigned to 'Alarms Eng Reset'.
14 - ATS Path Faults
Areas assigned to 'ATS Path Faults' (ATS = Alarm Transmission
System) will respond as follows when an ATS fault occurs.
All keypads will display 'ATS Path Fault'
All keypads and speakers assigned to the same area as the
'ATS Path Fault' will generate a Service tone every 30 Seconds
until the fault is acknowledged by the User entering a valid code
for that area
An assigned area can be armed, as long as 'Arm With No ATS' is
also assigned to that area (see option 16). However, a warning will
be given to indicate the problem
Areas not assigned to 'ATS Path Faults' will never be affected by an
ATS fault.
15 - Arm With No ATS
Areas assigned to 'Arm With No ATS' (ATS = Alarm Transmission
System) can be armed when an ATS fault occurs in those areas (see
option 15).
Areas not assigned to 'Arm With No ATS' can never be armed when
an ATS fault occurs in those areas (see option 15).
16 - AC Mains Fail
Areas assigned to 'AC Mains Fail' will respond as follows when an AC
mains failure occurs.
All keypads will display 'AC Mains Fail'
All keypads and speakers assigned to the same area as the 'AC
Mains Fail' will generate a Service tone every minute until the
fault is acknowledged by the User entering a valid code for that
area
An assigned area can be armed, as long as 'Arm With AC Fail' is
also assigned to that area (see option 18). However, a warning will
be given to indicate the problem
Areas not assigned to 'AC Mains Fail' will never be affected by an AC
mains failure.
17 - Arm with AC Fail
Areas assigned to 'Arm With AC Fail' can be armed when an AC Mains fail
occurs in those areas (see option 17).
Areas not assigned to 'Arm With AC Fail' can never be armed when an AC
Mains fail occurs in those areas (see option 17).
18 - Full Arm Coms
Areas assigned to 'Full Arm Coms' will respond as follows:
Area Programming