4 Refit the safety guard and tighten the screws (see point 1).
Active carbon filter and molecular sieve
Active carbon filter and molecular sieve
Active carbon filter and molecular sieve
Active carbon filter and molecular sieve
Active carbon filter and molecular sieve
The cartridges must be replaced before the air becomes foul-smelling.
The quality of the air depends to a large extent on the condition of the filtering cartridge. For this reason,
it is important to comply with the intervals as specified.
The frequency of replacement has been calculated for use of the compressor with intake air at a tempe-
rature of 20 °C (68 °F), see table 4. If the temperatures differ, apply the coefficients given in the following
table 3 to the duration of the filter:
Table 3
Maintenance
°C
°F
50
122
40
104
30
86
20
68
10
50
5
41
0
32
3 Remove the filter and replace it with a new
one (Fig. 81).
To order a new spare filter, refer to chapter
14 "Spare parts".
Multiplicative
coefficients
0.20
0.34
0.57
1
1.85
2.60
3.80
55
11.6
11.6
11.6
11.6
11.6