13 Inspection and maintenance
13.5 Installing the compressor
Risk of crushing due to the compressor
shutting down!
▶ Severe injury due to crushing or shear-
ing of the fingers.
Ensure that the actuator remains in the
●
open position while replacing the com-
pressor.
Do not reach into the tube crushing
●
area.
1. Remove the tube (see "Removing the tube", page 99).
2. Disassemble the tube holder (see "Disassembling the tube
holder", page 99).
3. Disassemble the compressor (see "Disassembling the
compressor", page 99).
4. Insert the compressor 2 and press upwards until the com-
pressor engages.
5. Move the actuator A to the open position.
13.6 Assembling the tube holder
1. Disassemble the tube holder (see "Disassembling the tube
holder", page 99).
2. Insert the tube holder 1.
3. Tighten the fixing screw c using an Allen key.
13.7 Inserting the tube
1. Remove the tube (see "Removing the tube", page 99).
2. Insert the tube.
GEMÜ Q50 eSyStep
CAUTION
2
1
c
3. Close the tube holder 1.
4. Turn the locking ring b by 90° in the direction of the arrow.
ð The word "locked" can be read on the tube holder.
5. With the valve fully assembled, check the function and
tightness.
100 / 108
1
b
www.gemu-group.com