Configuring the System using the VxFlex OS GUI
Using the Backend view Remove command
Dell EMC VxFlex Ready Node AMS User Guide
196
2. Locate the physical disk:
a. From the VxFlex OS GUI Hardware view, right-click the node, and select
Set Identification LED.
b. In the Set Identification LED dialog, select Turn On, and then click OK.
c. From the VxFlex OS GUI Hardware view, right-click the faulty disk, and
repeat the same steps.
The LEDs flash until turned off.
3. Use the blinking LEDs on the node and disk to identify them in the Data Center.
Ensure that the node S/N and the disk slot match the information gathered
previously. After the disk is removed, stop the blinking LED on the node.
Results
To add a replacement device, proceed to
About this task
This topic explains how to remove a device using the Remove command in the
Backend view. This command completely removes the device from the system. This
procedure can only be used to remove a device providing storage. It cannot be used
for a device providing caching.
Removal operations that are waiting in the job queue are shown as Pending. If a job in
the queue is going to take a long time, and you do not want to wait, you can cancel the
operation using the Abort button in the Remove command window (if you left it
open), or using the Abort command from the Command menu.
NOTICE
The Remove command deletes the specified objects from the system.
Use the Remove command with caution.
Procedure
1. In the Backend view, navigate to the desired device in the table, and select its
row.
2. Right-click the desired device and select the desired Remove command.
a. In the Remove Device dialog, for NVMe SSD devices that you want to
physically retain in the chassis, clear the Prepare Devices for Removal
option. For physical NVMe SSD device removal, leave this option selected.
b. In the Remove Device dialog, for NVMe SSD devices, it is recommended to
leave the Approve reconfigure SVM option selected.
A short window of Maintenance Mode may be initiated on the node during
the rebuild. If the node contains an MDM, it is preferable that the system is
running a 5-node MDM cluster.
c. For all device types, click OK.
In the confirmation window, click OK.The progress of the operation is
displayed at the bottom of the window. It is recommended to keep the
window open until the operation is completed, and until you can see the
result of the operation. For some objects, an Abort button is available in the
window, which can be used if you decide to abort the operation. There is
also an Abort command accessible from the Command menu.
Adding devices
on page 192.