Page 1
INSTALLATION AND USE INSTRUCTIONS CHAIN ACTUATOR FOR ACK5 WINDOW AUTOMATION PATENTED COD. 0P5018 VER.0.0 REV.05.17 BEFORE INSTALLING AND USING THE ACTUATOR, IT IS COMPULSORY FOR THE INSTALLER AND THE USER TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS.
ACK5 INDEX EC DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY ............................page 04 2- GENERAL REMARKS 2.1- General instructions ..................page 05 2.2- Installer and user ....................page 05 2.3- Warranty ......................page 05 2.4- Technical assistance ..................page 05 2.5- Reserved rights ....................page 05 2.6- Description of personnel ...................page 06...
Page 4
36066 Sandrigo (VI) Italia herewith declares that the person authorised to compile the technical file is Name: Bettiati Roberto - Topp S.r.l. Address: via Galvani,59 36066 Sandrigo (VI) that to the partly completed machinery CHAIN ACTUATOR FOR WINDOW AUTOMATION Type:...
ACK5 GENERAL REMARKS -2 2.1- GENERAL INSTRUCTIONS BEFORE INSTALLING AND USING THE ACTUATOR, IT IS COMPULSORY THAT THE INSTALLER AND THE USER CAREFULLY READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS. THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR AND MUST COMPULSORILY BE PRESERVED FOR FUTURE REFERENCE.
2- GENERAL REMARKS ACK5 2.6- DESCRIPTION OF PERSONNEL USERS MUST NEVER PERFORM OPERATIONS RESERVED FOR MAINTENANCE PEOPLE OR SPECIALISED TECHNICIANS. THE MANUFACTURER DECLINES ALL LIABILITY FOR DAMAGE DERIVING FROM FAILURE TO OBSERVE THE ABOVE REQUIREMENTS. Specialised electrician: A specialised electrician must be able to install the actuator, start it and operate it both in normal conditions and in the maintenance mode;...
• type of service S (min) • idle translation speed (mm/s) • protection degree (IP) • "CE" marking • symbol of “WEEE” Directive 2002/96/CE • symbol of double insulation (only for mod. ACK5/230V) • serial number INSTALLATION AND USE ISTRUCTIONS...
3- TECHNICAL DESCRIPTION ACK5 3.2- DENOMINATION OF THE COMPONENTS AND DIMENSIONS Fig. 2 Dimensions in mm LEGEND: 1) Power supply cable 2) Support heads 3) Support 4) Opening stroke adjustment on both sides 5) Actuator 6) Chain pin 7) Bracket for bottom hung opening...
ACK5 TECHNICAL DESCRIPTION -3 3.3- TECHNICAL DATA Tab. 1 contains the technical data characterising the actuators. ACK5/230V ACK5/24V Power supply voltage 230 V - 50 Hz 24 V 0,32 A 1,35 A Absorbed current Absorbed power with load 75 W...
3- TECHNICAL DESCRIPTION ACK5 3.4- FORMULAS FOR THE CALCULATION OF THRUST AND TRACTIVE FORCE Fig. 3 Horizontal domes or skylights F = Force necessary for opening or closing P = Weight of the skylight or dome (Only movable part) F = 0,54 x P Fig.
ACK5 TECHNICAL DESCRIPTION -3 3.6- USE LIMITS The actuator has been designed and manufactured exclusively for the destination of use given in par .3.5, therefore, any other type of use is strictly forbidden in order to assure in any moment the safety of the installer and of the user, as well as the efficiency of the actuator itself.
Page 12
3- TECHNICAL DESCRIPTION ACK5 Fig.5 INSTALLATION AND USE ISTRUCTIONS...
ACK5 SAFETY -4 4.1- GENERAL INSTRUCTIONS OPERATORS MUST BE INFORMED OF ACCIDENT RISKS, SAFETY DEVICES AND THE GENERAL ACCIDENT PREVENTION REGULATIONS ESTABLISHED BY INTERNATIONAL DIRECTIVES AND BY THE LAW IN FORCE IN THE COUNTRY OF USE. ALL OPERATORS MUST STRICTLY COMPLY WITH THE ACCIDENT PREVENTION REGULATIONS IN FORCE IN THE COUNTRY OF USE.
4- SAFETY ACK5 3) Only for the mod. ACK5/230V provided with protection against electric shocks: Protection of passive type given by the use of components with double insulation, also called components of class II or with equivalent insulation. 4.3- SAFETY PLATES IT IS FORBIDDEN TO REMOVE, MOVE, SPOIL OR IN ANYWAY REDUCE THE VISIBILITY OF THE SAFETY PLATES.
ACK5 INSTALLATION -5 5.1- GENERAL INSTRUCTIONS THE ACTUATOR INSTALLATION CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION. THE ACTUATOR PERFORMANCE MUST BE SUFFICIENT TO ASSURE THE CORRECT MOVEMENT OF THE WINDOW.
5- IINSTALLATION ACK5 Fig. 8 5.2- TOP HUNG WINDOWS (Fig. 8 and 16÷26) 1) Open the package (par. 3.7) and extract the various components; 2) Fig. 17- With a pencil draw the centre line "X" of the window frame; 3) Fig. 18- Select the following components: bracket "S1", support "SA", two nuts "D1", two...
ACK5 INSTALLATION -5 10) Fig. 23- Mount the nut "D2" on the screw "V3" and then it on the chain ending "TC"; Fig. 24- Connect the bracket "S1" to the screw "V3" by means of the pin "P"; 11) Perform the electric connections according to the prescriptions of par. 5.4, as well as with reference to the wiring diagram;...
Page 18
5- INSTALLATION ACK5 6) With a suitable drill, create on the window frame holes given on the adhesive template "DV"; 7) Fig. 32- Mount the support "SA" on the fix window frame with the screws "V2"; check the perfect horizontal and vertical alignment with the window frame;...
COUNTRY OF INSTALLATION ISSUING TO THE CUSTOMER A DECLARATION OF CONFORMITY FOR THE CONNECTION AND/OR THE PLANT PERFORMED. THE ELECTRIC CONNECTION OF THE VERSION ACK5/24V HAS TO BE CARRIED OUT WITH A VERY LOW SAFETY VOLTAGE FEEDER PROTECTED AGAINST SHORT CIRCUITS.
Page 20
To these control units, it is possible to connect the rain sensors (RDC - 12V), the wind sensor (RW) and the brightness sensor; THE EVENTUALLY USED UNITS MUST SUPPLY A VOLTAGE TO ACK5 FOR MAX. 120 s. 3) SYNCHRONIZATION UNIT:...
ACK5 INSTALLATION -5 5.7- EMERGENCY PROCEDURES Should it be necessary to open the window manually due to power supply failure or mechanism block, follow these instructions: BEFORE PERFORMING ANY TYPE OF INTERVENTION ON THE ACTUATOR AND ON THE WINDOW, IT IS COMPULSORY TO DISCONNECT THE POWER SUPPLY OF THE ACTUATOR AND TO PUT ON "0"...
6- USE AND OPERATION ACK5 6.1- USE OF THE ACTUATOR THE ACTUATOR CAN BE USED ONLY BY A USER ACTING IN COMPLIANCE WITH THE INSTRUCTIONS GIVEN IN THIS MANUAL AND/OR IN THE MANUAL OF THE ACTUATOR COMMAND DEVICE (e.g.: WIND AND RAIN CONTROL UNIT).
This maintenance activity may be carried out either by TOPP, in accordance with a specific agreement made with the user, or by the installation technician or by other competent and qualified technical personnel in possession of all legal requirements.
8- DEMOLITION ACK5 8.1- GENERAL INSTRUCTIONS THE DEMOLITION OF THE ACTUATOR MUST OCCUR IN COMPLIANCE WITH THE LAWS IN FORCE ON ENVIRONMENT PROTECTION. DIFFERENTIATE THE PARTS MAKING UP THE ACTUATOR ACCORDING TO THEIR DIFFERENT MATERIAL TYPE (PLASTIC, ALUMINIUM, ETC.). 9- SPARE PARTS AND ACCESSORIES UPON REQUEST ACK5 9.1- GENERAL INSTRUCTIONS...
Page 25
SPARE PARTS AND ACCESSORIES UPON REQUEST -9 ACK5 Fig. 13 FRAME ADJUSTMENT PINS INSTALLATION AND USE ISTRUCTIONS...
Page 26
9- SPARE PARTS AND ACCESSORIES UPON REQUEST ACK5 Fig. 14 VERTICAL MOUNTING BRACKET (COD. 3A1380-81-82) WING FRAME Window frame FOR A CORRECT OPERATION, THE WINDOW MUST HAVE A MIN. Overlapped part adjustment HEIGHT OF 800 mm (ACTUATOR DISTANCE FROM THE WINDOW pin code FRAME OPENING HINGE).
Page 27
SPARE PARTS AND ACCESSORIES UPON REQUEST -9 ACK5 Fig. 15 SMALL SWIVEL BRACKET (COD. 3A1396-97-98-99) WING Make sure that the M6 nut is tightly fastened M6 nut FRAME Window frame Overlapped part adjustment pin code 0B0008 ÷ 10 mm (Standard) BIG SWIVEL BRACKET (COD.3A1391-92-93-94)
Page 28
ACK5 INSTALLATION ON TOP HUNG WINDOWS Fig. 16 0÷10mm (Standard) Wing 45.5 Frame 27.5 55.2 96.7 Window frame Overlapped part adjustment pin code 0B0008 ÷ 10 mm (Standard) ÷ 20 mm 0B0005 ÷ 30 mm 0B0007 ÷ 40 mm 0B0006...
Page 29
ACK5 INSTALLATION ON TOP HUNG WINDOWS Fig. 17 Fig. 18 T1 T2 Fig. 19 Fig. 20 Fig. 21 INSTALLATION AND USE ISTRUCTIONS...
Page 30
ACK5 INSTALLATION ON TOP HUNG WINDOWS Fig. 23 Fig. 22 Fig. 24 Fig. 25 Fig. 26 INSTALLATION AND USE ISTRUCTIONS...
Page 31
ACK5 INSTALLATION ON BOTTOM HUNG WINDOWS Fig. 27 96.3 APPLICATION 1 55.2 T1 and T2 head downwards 27.5 0÷5mm Frame Wing 105÷110 96.3 55.2 27.5 0÷5mm APPLICATION 2 Frame T1 and T2 head upwards Wing 105÷110 VERIFY THAT THE DISTANCE "D" BETWEEN THE FIXED PART AND THE MOVABLE PART OF THE WINDOW IS INCLUDED WITHIN 0 AND 5 mm.
Page 32
ACK5 INSTALLATION ON BOTTOM HUNG WINDOWS Fig. 28 Fig. 29 Fig. 30 Fig. 31 Fig. 32 INSTALLATION AND USE ISTRUCTIONS...
Page 33
ACK5 INSTALLATION ON BOTTOM HUNG WINDOWS Fig. 33 Fig. 34 SA S2 Fig. 35 Fig. 36 S2 S3 V4 Fig. 37 INSTALLATION AND USE ISTRUCTIONS...
Page 34
ACK5 DRAWINGS FOR INSTALLATION Wiring diagram INSTALLATION AND USE ISTRUCTIONS...
Page 36
TOPP S.r.l. Società a Socio Unico soggetta a direzione e coordinamento di 2 Plus 3 Holding S.p.a. Via Galvani, 59 - 36066 Sandrigo (VI) - Italia Tel. +39 0444 656700 - Fax +39 0444 656701 Info@topp.it - www.topp.it...
Need help?
Do you have a question about the ACK5 and is the answer not in the manual?
Questions and answers