Anomaly
Type of
Description
anomaly
N°221
Stops
Boiler over tem-
cycle (if
perature (TBOI).
EtUb
the boiler
is used).
N°211
Stops
Cavity over
cycle.
temperature
EtUC
(TCAV).
N°324
After
Oven worked 8
ending
hours without
FA8H
cooking
air inlet filter.
cycle,
blocks
oven
cooking.
Lower Motor
N°450
Stops
machine.
Short Circuit.
Fd00
N°451
Stops
Lower motor
overcurrent.
machine.
Fd01
Possible
Instructions to User
causes
Missing water in
-Wait for the boiler tem-
the boiler (elec-
perature to cool down
tric heated units
(alarm ETUB will
only); Limestone
disappear);
accumulation in
For Digit oven version
the boiler; The
run a cleaning program
parameter BOT
including the rinse and
is set too low.
descale cycle and use 2
tabs "C25" only.
For Touch oven version
perform the Boiler Main-
tenance procedure.-
(Follow the procedure as
per User Manual); In
case the alarm re-
appears, descale the
boiler again.
If the problem persists,
call Service.
The cavity is
Launch a cooling cycle; if
dirty; The
not possible open the
parameter COT
door and let the oven to
is set too low.
cool down; clean the
cavity. When the temper-
ature drops it is possible
to launch a new cooking
cycle.
If the problem persists,
call Service.
Restore the air
Restore the air intake
intake filter
filter.
checking that it
is clean before
fitting it back in
place.
Pinched wire
Call Service.
(line between
inverter and
motor). Short
circuit phase to
phase. Short cir-
cuit phase to
ground. Inner
electric motor
shortcut.
All causes
Restart oven.
related to friction
If the causes persist,
phenomena:
error will appear again,
- Cavity fan
call Service.
towards suction
wall.
- Motor shaft
towards graph-
itic ring.
Action for Service*
Descale boiler
For level Touch D.3 Level T, K
(TOUCH SCREEN)
For level B (Digit) D.4 Level B, C
(DIGIT)
Check cavity temperature sensor
readings (see "Cavity probe
(TCAV)" section in "Servicing the
appliance" chapter of the proper
Service manual).
Check correct cavity temperature
sensor positioning (5 mm gap
from protection plate inside the
cavity)
Replace temperature sensor (see
"Cavity (TCAV)" section in
"Detailed appliance and compo-
nents description/functioning"
chapter of the proper Service
manual).
Fix the short-circuit in case it is
related to the harness.
Replace the motor if the issue is
within the motor winding (see
"Inverter (MD/motor drive" section
in "Detailed appliance and com-
ponents description/functioning"
chapter of the proper Service
manual).
Ensure the cavity fan does not
interfere with suction wall. In case
fix the interference by ensuring
the proper positioning of the suc-
tion wall.
Replace graphitic rings and clean
the motor shaft prior to reassem-
ble (see "Inverter (MD/motor
drive" section in "Detailed appli-
ance and components
description/functioning" chapter
of the proper Service manual).