Anomaly
Type of
Description
anomaly
N°243
Warning
Error, excessive
time on closing
BEtc
operation of the
vent valve
during cleaning
(VV1).
N°242
Stops
Error, excessive
cleaning.
time on opening
BEto
operation of the
vent valve
during cleaning
(VV1).
N°224
Warning
Boiler exces-
sive tempera-
BEtr
ture raising time
(Tbol).
N°241
Warning
Warning on
excessive time
Bhtc
on closing oper-
ation of the vent
valve during
cooking (VV1).
Possible
Instructions to User
causes
Mechanical or
The oven has detected a
electrical prob-
problem with cavity vent
lem with vent
operation. If cooking:
valve.
check the cooking result,
try to reset the message
also switching OFF/ON;
if message persists, call
Service and continue
cooking: clean the oven
only manually until fixing
the issue.
If cleaning: it is not possi-
ble to perform/complete
the cleaning cycle.
Switch OFF/ON to reset
the message. If the prob-
lem persists, call Service.
Mechanical or
The oven has detected a
electrical prob-
problem with cavity vent
lem with vent
operation. It is not possi-
valve.
ble to perform/complete
the cleaning cycle.
Switch OFF/ON for reset-
ting the error.
If the cleaning does not
restart, call Service.
- Broken heating
The oven has detected a
element.
low performance in the
boiler. Please verify
- Broken Solid
cooking results.
State relay.
- Dirty burner.
- Flap (venting
It is possible to continue
valve) motor
using the oven; Cooking
reducer or micro
results maybe different
switch failure.
from usual (probably
dryer than usual); With
- Obstruction at
the oven OFF and cold,
the venting
check if any obstruction
valve inlet.
at the ventilation chimney
on the top of the oven. If
the warning persists, call
Service.
Action for Service*
Check cleanness of vent valve.
Check X35 and X46 on ACU (see
E.4 A.C.U Level T ,K, B, C
(Power Board) section.
Verify harness continuity and con-
nectors (see "Venting valve, VV1"
section in "Detailed appliance
and components description/
functioning" chapter of the proper
Service manual).
Replace vent valve (see "Cavity
air valve" section in "Servicing the
appliance" chapter of the proper
Service manual).
Restart the oven to let the clean-
ing procedure to complete.
Check cleanness of vent valve.
Check X35 and X46 on ACU
(seeE.4 A.C.U Level T ,K, B, C
(Power Board))
Verify harness continuity and con-
nectors (see "Venting valve, VV1
" section in "Detailed appliance
and components description/
functioning" chapter of the proper
Service manual).
Activate the vent valve from by-
pass environment to check func-
tionality D.3.2.2 By-Pass
environment
Replace vent valve (see "Cavity
air valve" section in "Servicing the
appliance" chapter of the proper
Service manual).
Restart the oven to let the clean-
ing procedure to complete.
Verify boiler heating element;
Solid state relay; Burner clean-
ness; PWM malfunctioning/wrong
values.
Check cleanness of vent valve.
Check X35 & X46 on ACU E.4 A.
C.U Level T ,K, B, C (Power
Board)
Verify harness continuity and con-
nectors (see "Venting valve, VV1"
section in "Detailed appliance
and components description/
functioning" chapter of the proper
Service manual).
Activate the vent valve in Service
mode to check functionality.
Replace vent valve (see "Cavity
air valve" section in "Servicing the
appliance" chapter of the proper
Service manual).
Restart the oven to let the clean-
ing procedure to complete/heck
that the warning disappeared.